System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Configuration
Aastra Proprietary Information Page 2-55
Common conference circuit
The schematic drawing depicted below shows a conference circuit with all
subscribers participating in the same
conference.
Subscribers 1 to 6 in nodes 1, 2, 3 and 4 all participate in a common
conference.
Main line
The main line of the conference is routed in channel 11 from node 1 via
node 2, port 1, and node 2, port 3, to node 3.
In node 2, this channel 11 is switched from port 1 to converter 1 and from
port 3 to converter 2 in the STANDARD operating mode (port <->
converter).
Node 3, i.e. the end node of the main line, is not configured for an EDC.
Here subscriber 5 is configured for the STANDARD operating mode with
channel 11.
Sub-line
Subscriber 6 in node 4 is to participate in the conference in node 2 via a
sub-line.