Operation Manual
40 Parameters
4.11.2 Resonant High-Pass Filter
Amplitude (dB)
Frequency (Hz)
0dB
−3dB
Cutoff
Frequency
Slope (dB/Oct)
Q=2
Q=1
Q=4
Q=10
Figure 20: Frequency response of the high-pass filter.
The high-pass resonant filter works in exactly the opposite manner as the low-pass resonant
filter by removing the frequency component of a signal located below the cutoff frequency while
leaving those above the cutoff frequency unchanged. Similarly to the low-pass filter, the Q-factor
controls the emphasis of frequencies located around the cut-off frequency.
4.11.3 Band-Pass Filter
Amplitude (dB)
Frequency (Hz)
0dB
−3dB
Center
Frequency
Q=10
Q=4
Q=2
Q=1
Band Width (Q=1)
Figure 21: Frequency response of the band-pass filter.
The behavior of a band-pass filter is to let the frequencies in a band located around a center