Installation manual
8
TECHNICAL DATA
TECHNICAL DATA
Aarrow
ECB 5
Aarrow
ECB 7
Aarrow
ECB 9
Aarrow
ECB 11
Nominal Heat Output (Kw) 5.1 6.1 8.8 11
Efficiency Nett (%) 74.7 72.1 71.6 74.7
Mean Flue Gas Temperature (c) 306 363 364 370
Mean CO Emission @ 13% O2 (%) 0.58 0.58 0.68 0.71
Flue Mass Gas Flow (g/s) 4.4 4.9 6.9 6.9
Height (mm) 522 558 600 605
Width (mm) 397 476 586 672
Depth (mm) (Inc. Handle) 388 386 396 442
Height To Centre Of Rear Flue (mm) 424 449 485 478.5
Depth From Back To Centre Of Flue
(mm)
94 109 102.5 141
Flue Diameter (mm) 102 (4”) 127 (5”) 127 (5”) 152 (6”)
Weight Packed (Kg) 57 68 79 106
Weight Nett (Kg) 54 64 75 101
Aarrow Ecoburn Stoves
Minimum Distance To Combustible
Materials (mm)**
Rear– 625
Sides– 525
Rear– 650
Sides– 450
Rear– 750
Sides– 500
Rear– 800
Sides– 500
**NOTE : If the optional convector kit is to be fitted to the stove, the minimum distance
to combustible materials is REDUCED to the following dimensions :
Minimum Distance To Combustible
Materials (mm) With Convector Kit
Fitted
Rear– 450
Sides– 450
Rear– 500
Sides– 450
Rear– 410
Sides– 380
Rear– 550
Sides– 460