Energy Guide
Page 5 of 7 Report No.: GZES191002582231
TRF: 10CFR430.23(b)_02- DOE
Sample No.
Sample 1
Sample 2
Sample 3
First test /
Thermostat setting
Medium position
Medium position
Medium position
Temperature in wine
compartments (ºC)
t
1
= 6,12 ºC,
t
2
= 6,39 ºC,
t
3
= 4,82 ºC ;
t
avg
= 5,78 ºC
t
1
= 7,31 ºC,
t
2
= 6,51 ºC,
t
3
= 5,79 ºC ;
t
avg
= 6,54 ºC
t
1
= 4,75 ºC,
t
2
= 5,35 ºC,
t
3
= 3,48 ºC ;
t
avg
= 4,53 ºC
Power input(W)
58,7
58,8
61,8
Compressor operation
ratio
46%
43%
45%
Energy consumption
EP1 (kWh/d)
0,307
0,275
0,361
Time T1 (min)
657
598
741
Energy consumption ET1
(kWh/d)
0,370
0,364
0,386
Second test /
Thermostat setting
Warmest position
Warmest position
Warmest position
Temperature in wine
compartments (ºC)
t
1
= 9,95 ºC,
t
2
= 10,20 ºC,
t
3
= 8,82 ºC ;
t
avg
= 9,66 ºC
t
1
= 11,11 ºC,
t
2
= 10,48 ºC,
t
3
= 9,84 ºC ;
t
avg
=10,47 ºC
t
1
= 8,54 ºC,
t
2
= 9,07 ºC,
t
3
= 7,38 ºC ;
t
avg
=8,33 ºC
Power input(W)
59,0
60,0
62,7
Compressor operation
ratio
43%
35%
36%
Energy consumption
EP2 (kWh/d)
0,246
0,250
0,278
Time T2 (min)
629
651
687
Energy consumption ET2
(kWh/d)
0,310
0,304
0,325
Interpolation
Energy consumption ET
(kWh/d)
for 55°F
0,310
0,304
0,325
The higher of year energy
consumption (kWh/year)
113,150
110,960
118,625