Installation & Assembly
For best results, use Aamsco Alinea lamps only. Use of any unauthorized light source will void
warrantee.
Rev. 519
MOUNTING VARIATIONS
A.
Use of a remote junction box (up to 6 ft. away), recommend using a 3/8" Greenfield with a 1/2"
connector.
B. Existing junction box cover (not included) can be used over existing outlet.
C. Recommend a 1/2" chase nipple and locknut for connecting fixtures together.
D. While the luminaires can be mounted end to end, it is not recommended that they be wired
together in series.
WIRING
A. Wiring is connected through the knockout hole provided. Wiring should be done by a qualified
electrician in accordance with state and local electrical codes. The fixture should be protected by a
ground fault circuit interrupter when installed in bathrooms or other damp locations.
B. Connect supply wires as follows: Supply black (hot) to fixture black (hot); supply white
(common) to fixture white (common); supply green (ground) to fixture green (ground).
LAMPING