User Manual
12
NOTE 1: Shipping weight does not include motor and drive.
NOTE 2: Operating weight includes estimated weight for motor and drive for Arrangements “A” and “D”.
Also includes maximum sludge capacity based on 100 lb. per cubic foot for Arrangement D hopper in the
event of plugged drain line.
Table 2. Shipping and Operating Weight in Pounds
RotoClone Arrangement A Arrangement D
Size Shipping Weight (lbs.) Operating Weight (lbs.) Shipping Weight (lbs.) Operating weight (lbs.)
8 225 425 1,725 2,625
10 360 610 1,810 3,010
12 630 880 2,030 3,380
14 990 1,340 2,790 5,320
16 1,260 1,710 3,760 6,310
20 1,620 2,270 5,420 9,650
24 1,890 2,590 7,190 13,290
27 2,970 3,720 -- --
30 3,870 5,020 -- --
33 4,860 6,360 -- --
36 5,850 7,350 -- --
45 13,500 16,000 -- --
6.0 Weights & Water Usage Tables
Table 1. Normal Water Supply Rates - Type W RotoClones
Size
Arrangement A Arrangement D
GPM Supplied GPM Supplied
40 psi 50 psi 60 psi 40 psi 50 psi 60 psi
8 1.1 1.2 1.3 2.1 2.2 2.5
10 1.5 1.6 1.8 3.1 3.4 3.8
12 1.8 2.0 2.2 4.8 5.4 5.9
14 2.3 2.5 2.9 5.3 5.9 6.5
16 3.5 3.9 4.3 7.5 8.4 9.2
20 4.5 5.0 5.5 8.5 9.5 10.4
24 5.5-6.0 6.2-6.7 6.8-7.3 13.5-14.0 15.1-15.6 16.6-17.1
27 7.0-7.5 7.9-8.4 8.7-9.2 ---- ---- ----
30 8.0 8.9 9.8 ---- ---- ----
33 12.0 13.4 14.7 ---- ---- ----
36 14.0-15.0 14.7-15.7 16.7-17.1 ---- ---- ----
45 21.0-22.0 23.6-24.6 25.9-26.9 ---- ---- ----
NOTE 1: Decreased or increased water requirements can be provided by changing nozzle size.
NOTE 2: For air temperatures in excess of 300° F cooling spray nozzles should be provided in inlet duct to compensate for evaporation.
A safe approximation will be 0.2 GPM of additional water per 1000 CFM for each 100° F temperature reduction.