User`s manual

Users Manual
38 ECM-5716 Series Users Manual
3.7.39 Signal Description 10/100/1000Base-Tx Ethernet Connector
MDI (0) +/- Media Dependent Interface (0)
1000BASE-T: In MDI configuration, MDI (0)+/- corresponds to BI_DA+/-, and in MDI-X
configuration, MDI (0) +/- corresponds to BI_DB+/-.
100BASE-TX: In MDI configuration, MDI (0)+/- is used for the transmit pair, and in MDI-X
configuration, MDI (0) +/- is used for the receive pair.
10BASE-T: In MDI configuration, MDI (0)+/- is used for the transmit pair, and in MDI-X
configuration, MDI (0) +/- is used for the receive pair.
MDI (1) +/- Media Dependent Interface (1)
1000BASE-T: In MDI configuration, MDI (1)+/- corresponds to BI_DB+/-, and in MDI-X
configuration, MDI (1) +/- corresponds to BI_DA+/-.
100BASE-TX: In MDI configuration, MDI (1)+/- is used for the receive pair, and in MDI-X
configuration, MDI (1) +/- is used for the transit pair.
10BASE-T: In MDI configuration, MDI (1)+/- is used for the receive pair, and in MDI-X
configuration, MDI (1) +/- is used for the transit pair.
MDI (2) +/- Media Dependent Interface (2)
1000BASE-T: In MDI configuration, MDI (2) +/- corresponds to BI_DC+/-, and MDI-X
configuration, MDI (2) +/- corresponds to BI_DD+/-.
100BASE-TX: Unused.
10BASE-T: Unused.
MDI (3) +/- Media Dependent Interface (3)
1000BASE-T: In MDI configuration, MDI (3) +/- corresponds to BI_DD+/-, and MDI-X
configuration, MDI (3) +/- corresponds to BI_DC+/-.
100BASE-TX: Unused.
10BASE-T: Unused.
3.7.40 Parallel Port Connector (LPT)
Signal PIN Signal
NC 26
13
SLCT
GND 25
12
PE
GND 24
11
BUSY
GND 23
10
ACK#
GND 22
9
PD7
GND 21
8
PD6
GND 20
7
PD5
GND 19
6
PD4
GND 18
5
PD3
SLIN# 17
4
PD2
INIT# 16
3
PD1
ERR# 15
2
PD0
AFD# 14
1
STB#