Breakdown help when the automatic diaphragm and
shutter drive are defective
Should the servo motor used for the automatic diaphragm
setting become defective, the automatic and iris shutter
functions can still be operated when the following steps are
taken:
First remove the magazine from the camera (see changing
120 m magazine) so that the film channel is visible.
Then remove the black round sticker (a) which is found to
the right of the film channel on the cover plate. Beneath it is
a screw; turn it clockwise through approx. 90° and replace
the sticker.
The camera can now be used again and the automatic
diaphragm function is again operative.
The iris shutter f-stop must however-be manually set in
conjunction with the manual exposure meter.