Instruction manual

damage to parts which have become sluggish. The inching
system can be switched on by depressing the small red test
button (30).
An overload fuse switches the camera off automatically if
power consumption exceeds approx. 4.5 A. If this happens,
the camera must be switched off with the housing switch and
the cause of the overload must be located and eliminated
(e.g. film jam) before switching the camera on again.
The drive motor and its electrical control system, pilot
tone and start marking.
A quartz controlled 12 V DC motor drives the camera.
Frame rates of 24 and 25 fps can be selected (see para.:
switching over from 24 - 25 fps, and/or 50 - 60 Hz). Pilot
frequencies of between 50 and 60 Hz, proportional to the
camera motor speed, can also be selected. Synchronous
double system recording is possible with this camera using
the following methods:
1. Conventional pilot tone method; including start marking
(with cable).
2. Quartz pilot frequency method, without start marking,
using a quartz synchronous tape recorder.
3. Quartz synchronous time-coding method.
The current load of the motor is limited to 5 A. The current
load at room temperature is about 1 A.