Instruction Manual

SPECIFICATIONS
SP SERIES
Model SP-3 SP-5 SP-8 SP-16
Ozone output g/h 3 5 8 16
Concentration g/m3 Oxygen : 25-45 Air: 5-15
Electric 220/240 OR 110/120 VAC 50/60 Hz
Power Watt 80 95 110 190
Size Inch 11X8X14.3 12X8X14.3 15X8X18
Weight lbs 14 14.5 16 22.5
Cooling System Air Cooling Fan
Gas Feed Oxygen or Clean Dry Air
Suggested ozone concentration and run-time in Swimming Pools
Ideal pump run time on 24 hour cycles. If user chooses to run pump on 12-hour cycle time then
water circulating rate should be once each 3 to 4 hour period. The pump should re-circulate the
total volume of pool water through the injector at least once each 4 hr period for maximum
liters.
Swimming pool based on 24-hour run-time
Pool Size in Liters, Gallon
25000 L, 6600 G
50000 L, 13000 G
100000 L, 26000 G
200000 L, 52000 G
Heated swimming pools and rock pools require 10 - 15% more ozone.
Basic conversions
Mete
rs (L) x Meters (W) x Meters (D) = cubic meters x 1000 = Total Liter
s
Cubic Meters to Lit
ers: Cubic Meters x 1000 = Total Liters
Cubic Meter/3.785= Gallon
5