Specifications

30
5 Menus and settings (continued)
5.4 Service management (cont.)
Table Management
In this menu you can set static
NIT and static SDT if wanted.
This can be helpful if there are
changes in the transmissions
from the source that is unwanted
to affect the NIT table version to
avoid to get a message “New
channels found, Do you want to
do a new channel search?” on
digital receivers (STB’s or TV’s)
or if the EXM units are not
connected to a switch, static NIT
shall be used.
Actual table version of the NIT
and SDT can be seen on the left
of the scroll lists.
NOTE 1: If you use this function
you must manually change the
number of the static NIT and/or
SDT every time you remove a
service, add a service, change
LCN or do another change that
you want to send the correct table
information to the digital
receivers.
In the Table Configuration you
can see the included tables of
NIT and SDT and the repitition
rate of the tables and the average
output bitrate of those tables.
NOTE 2: The repitition rate can
be adjusted but this shall NOT be
changed in a normal installation.
English