Datasheet
Product Name: High Power Lithium Ion Cell, Phosphate-Based
Revision Date: July 1, 2011
Page 5 of 9
SAFETY DATA SHEET
According to Regulation (EC) No. 1907/2006
SF000003 REV 20
Section 8: Exposure Controls/Personal Protection
Exposure Limit Values:
Airborne exposures to hazardous substances are not expected when product is
used for its intended purpose.
Engineering Controls:
Use local exhaust ventilation or other engineering controls to control sources
of dust, mist, fume and vapor.
Personal Protection:
Respiratory Protection:
Not necessary under normal conditions.
Skin Protection:
Not necessary under normal conditions. Wear neoprene or natural rubber
gloves if handling an open or leaking cell.
Eye Protection:
Not necessary under normal conditions. Wear safety glasses if handling an
open or leaking cell.
Other Protective Equipment:
Not necessary under normal conditions. Have a safety shower and eye-wash
fountain readily available in the immediate work area.
Hygiene Measures:
Do not eat, drink or smoke in work areas. Maintain good housekeeping.
Section 9: Physical and Chemical Properties
Physical State:
Solid
Vapor Pressure (mm Hg @ 20°C):
Not applicable
Appearance:
Cell
Vapor Density:
Not applicable
pH:
Not applicable
Solubility in Water:
Insoluble
Relative Density:
Not available
Water / Oil distribution coefficient:
Not applicable
Boiling Point:
Not applicable
Odor Type:
Odorless
Melting Point:
Not applicable
Odor Threshold:
Not applicable
Viscosity:
Not applicable
Evaporation Rate:
Not applicable
Oxidizing Properties:
Not applicable
Auto Ignition Temperature (°C):
Not applicable
Flash Point and Method (°C):
Not applicable
Flammability Limits (%):
Not applicable
Section 10: Stability and Reactivity
Stability:
Stable
Conditions to Avoid:
Avoid exposing the cell to fire or temperatures above 80°C. Do not
disassemble, crush, short or install with incorrect polarity. Avoid mechanical
or electrical abuse.
Incompatible Materials:
Do not immerse in seawater or other high conductivity liquids.
Hazardous Decomposition Products:
This material may release toxic fumes if burned or exposed to fire. Breaching
of the cell enclosure may lead to generation of hazardous fumes which may
include extremely hazardous HF (hydrofluoric acid).
Possibility of Hazardous Reactions:
Not available