Basic settings 
With the illumination switched off, rst press on one of the buttons to switch the illumination on and then continue with the setting. Having pressed the last button, 
the illumination will switch off after 2 min.
Menu structure at Basic level
 Good
 Operational status  Basic setting  Timeprog. options  Param Mode  Info
 Tech. Read-out
 CH prog    Set date and time    Boiler param    Cascade
 DHW prog    Timeprog. CH    Other
 Pump prg.    Timeprog. DHW 
 Timeprg. CH
 Timep. DHW
 CH temp
 DHW temp
 Units
 Language
 Restore Defaults
                  In the table below you nd all sub settings of each parameter.
Water pressure
When the screen shows ‘FILL’ the water pressure is too low. Press, if necessary 
the + or - button to read out the water pressure. Please contact your installer/
supervisor to check the installation and top up.
Turning the programs on or off
Proceed as follows:
  (Switch on the main power supply switch).
  From the standard blue illuminated screen:
  1. Press the right arrow button:
    Screen displays: Basic settings;
  2. Press OK;
  3. Press the right arrow button:
   Screen displays: CH prog off/on;
  4. Press the + (on) or - (off) key:
   Screen displays: CH prog on or off;
  5. Press OK;
  6. Repeat procedure from point 3 onward. 
   This switches off the functions DHW prog. and 
   Pump prg. respectively.
  7. Press the return button to return to the standard display.
  Depending  which  program  is  selected  the  corresponding 
symbol will be shown in the display.
In some cases it might be necessary to put the complete boiler out of operation. 
The boiler  is  put  out of  operation  by  switching off the three  functions  ( 
, 
 and/or   ). The frost protection will remain active. Leave gas supply open.
A.O. Smith recommends leaving the power switch switched on to ensure that the 
boiler pump(s) and three-way valve (if available) are automatically activated to 
prevent them from getting stuck.
If  your  heating  system  is  not  being  used  during  periods  of  frost  we 
advise you  isolate the power and drain the boiler and the system. In 
this case: close the gas valve.
Error, maintenance and warranty
If a fault is detected the boiler will be blocked. This will be reected, with an E 
for Error, a B for Blocking or M for Message and a number code on the display.
You can try  to reset the boiler by pressing the Reset key once.  If the problem 
remains please contact your installer and inform them about the fault and give 
them the number code.
If, on the screen the message “Service” appears, the installer must perform maintenance according to the installation and service manual. Please contact your installer.
We advise you to obtain a service contract with your installer for regular maintance and adjustment to keep your boiler safe and in good condition.
If you discover any leaks from the boiler contact your installer.
The casing of the boiler consists of metal and plastic parts which can be cleaned with a normal non abrasive cleaning agent.
Important! 
It is in your own interest to register your warranty, visit the website www.aosmithinternational.com/content/product-registration and ll in the Pro-
duct Registration Form. Registering the boiler gives the owner of the boiler supplied by A.O. Smith Water Heaters the right to the warranty which 
denes the commitments of A.O. Smith Water Heaters to the owner. You can nd the warranty conditions in the Installation and Service Manual 
which is supplied with the boiler.
 With the arrow buttons 
you can go through the 
different chapters.
  Press OK to select or to 
conrm a change.
  With the + and - button 
you can increase or 
decrease a selected 
value.
  Back to previous screen 
or standard read out: 
Press this ‘return-button’.
Basic settings Basic settings
PARA
factory
setting
Description Range
CH prog off CH-program on/off
DHW prog off DHW-program on/off
Pump prg off Pump program (frost protection) on/off
Timerpr CH off Clock program CH on/off
Timerp DHW off Clock program DHW on/off
CH temp 90
Adjusted maximum flow temperature in °C
(only active with connected outdoor sensor & P101=0)
10-90
DHW temp 65 Adjusted maximum DHW temperature in °C (only visible when DHW is activated) 10-80
Units SI Selection possibility units SI=Europe, Imp(erial)= USA SI/Imp
Language GB Language selection
GB, NL, I, D, F, 
PL, TR, DK, E
Restore defaults Reset of the factory settings (dependant of selected level)
Timeprog options Clock program options
PARA
factory
setting
Description Range
Set date and time
Set Time 00:00 Actual time setting in hours and minutes
Set Date DD-MM-YY Actual date setting day-month-year
Daylight saving Europe Zone for daylight saving Off-Eur-USA
12/24hrs 0-24h 12-hour (AM/PM) or 24-hour display AM/PM-24h.
Date format DD-MM-YY Reproduction of date display (DD-MM-YY, MM-DD-YY, YY-MM-DD)
Time prog CH (only visible when NOT OpenTherm or 0-10V)
Day temp T-day 20
Day temperature according heating line in °C 
(if outdoor sensor is NOT connected: max flow temp.)
10-30
(10-90)
Night temp T-night 15 Night temperature according heating line (Eco) in °C 10-30
Select Preset Preset 1 Choice for the preselected time programm CH 1 or 2
Adjust Timeprog
mo1 off
03:00
See table time programs CH
It is possible to select 4 switch moments (steps of 30 min.) per day.
Choice: day temperature, night temperature, off, - - -
Copy function to next day: after switch moment 4.
Store Preset Store of the adjusted time program for CH
Timepr DHW (only visible when NOT OpenTherm)
Select Preset Preset 1 Choice for the preselected time programm DHW 1 or 2
Adjust Timeprog
mo1 off
03:00
See table time programs DHW
It is possible to select 4 switch moments (steps of 30 min.) per day.
Choice: on, off, - - -
Copy function to next day: after switch moment 4.
Store Preset Store of the adjusted time program for DW
Param Mode Parameter chapter
PARA
factory
setting
Description Range
Boiler param
Boiler parameters
P132 1 Pump continuously 1-2
1:Unit
p
um
p
 P1
2 Unit 
p
um
p
 P1 and installation 
p
um
p
 P
3
Info Information
Cascade
Information of cascade system
T3 xx.x°C DHW temperature T3 in external cylinder in °C (if connected and P100 is selected for DHW)
T4 xx.x°C Outdoor temperature T4 in °C (if connected)
T10 xx.x°C Temperature T10 sensor in low velocity header in °C
Boiler
Information of the boiler
T3 xx.x°C DHW temperature T3 in external cylinder in °C (if connected and P100 is selected for DHW)
Others
Stand-by xx h  Number of hours stand by
Burn. On xx h  Number of running hours with burner on
Service xx h  Number of running hours to go for maintenance interval
Ignition xx Number of times ignition
Faults xx Number of times in error
   Basic
Settings
 CH prog
     off
 CH prog
      on
CH  DHW  Pump
Remark: Depending which 
parameter settings are set, some 
options will not be displayed.