Specifications

TroubleshootingGuide
8|Page
5.2TROUBLESHOOTING‐GENERALPROBLEMS
ProceedtotheErrorCodessectionifanerrorcodeisidentified.Forothercommonproblemsthatdo
notinvolveanerrorcode,seeifthefollowingitemshelp:
Thewaterisnothotenough.
Thewateristoohot.
Temperaturefluctuateswhenafixtureisopened.
Unitdoesnotignitewhenwatergoesthroughit.
Ittakesalongtimetogethotwateratthefixtures.
Thefanmotorisstillspinningafteroperationhasstopped.
Abnormalsoundscomefromtheunit.
Lossofpressureatallsinkswhenthedishwasher
fills.
Unithaspower,gas,andwaterbutdoesnotturnon.
MultipleHeaterSetup
THEWATERISNOTHOTENOUGH
Thesettemperaturemaybesettoolow.Thetemperaturecanbechangedwiththe
pushbuttonsonthePCBorbytheremotetemperaturecontroller,ifoneisinstalled.
Checktheflowandtemperaturerightattheunitatthepressurereliefvalvewithahandheld
thermometer.Ifthe
flowrateandtemperaturearecorrectatthePRV,thentheproblem
resideselsewhereintheplumbingline.Thefollowingcouldbeplumbinglineproblems:
o Checkforcrossplumbingbetweencoldwaterlinesandhotwaterlines.Seethe
Proceduressection(p.22)forinstructions.
o Checktosee
thatacheckvalveisinstalledbetweenthepumpdischargeandthe
connectiontothecoldwatersupply.Inspectthecheckvalveforproperoperation.If
thereisn’toneinstalled,orifitismalfunctioning,coldwatermaybebackfeedinginto
thesystem.
Unitmaybehardwaterscaled.
Thescaleactsasaninsulatorpreventingtheheatexchanger
fromtransferringheattothewater.
Theunitmaynotbereceivingenoughgas.
o Thegassupplyvalvemaynotbefullyopen.
o Thegaslinemaybesizedimproperly.
o Thegassupplypressuremaybe
toolow.Thismaybecausedbyamalfunctioninggas
supplyregulator,sochecktoseeifyourregulatorisworkingproperly.
Doublecheckfora101errorcode.A101errorcodewillreducetheamountofgasinputinto
theheater.
Outputtemperaturewillbeaffectedif
airflowisimpeded.Thiscouldincludeblockageinthe
ventingline,oraclogged/dirtyburnerfromcontaminatedintakeair.
THEWATERISTOOHOT
Thesettemperaturemaybesettoohigh.Thetemperaturecanbechangedwithdipswitcheson
thePCBorbytheremotetemperaturecontroller,ifoneisinstalled.
Theflowadjustmentvalvecouldbeobstructedduetohardwaterscaleordebris,causinglower
thanexpectedwaterflow.Verify
waterflowwithagraduatedcontainerorwiththeremote
temperaturecontroller,ifoneisinstalled.
Theoutputthermistorcouldbecompromised.Thiscomponentmaybecheckedbyenteringthe
DiagnosticsModeonaremotecontroller,ifoneisinstalled.Turnpowerofftotheunit andrun
cold
waterthroughit;checktoseeiftheinletandoutlettemperaturesreadthesameonthe