Specifications

TroubleshootingGuide
22|Page
4 ActivationofIndividualOperationmode
Enable
(Default)
Disable
5 Directventsetting EnableDirect
ventmode
Disable
(Default)
6 Outdoorsetting Enable
OutdoorMode
Disable
(Default)
7 Activationofcheckingtherecirculationpump Enable Disable
(Default)
8 Parent/ChildsettingonEasyLinksystems Parent Child
(Default)
DRAININGTHEUNIT:
1) Closethemanualgasshutoffvalve.
2) Turnoffpowertotheunit,andthenturnonagain.
3) Wait30seconds,andthenturnoffpowertotheunit,yetagain.
4) Closethecoldwaterinletshutoffvalve.
5) Openallhotwatertapsinthe
house,oropenthepressurereliefvalvetoremovetheinitial
pressure.Whentheresidualwaterflowhasceased,closeallhotwatertaps.
6) Unscrewthedrainplugs(hotwateroutletdrainplugandcoldwaterinletfilter)todrainthe
remainingwateroutoftheunit.Haveabucket
orpantocatchthewaterfromtheunit’s
drainplugs.Waitafewminutestoensureallwaterhascompletelydrainedfromunit.
CLEANINGTHE FILTER:
1) Draintheunit(procedureabove).
2) Checkthewaterfilterlocatedwithin
thecoldinlet.Withatinybrush,clean
thewaterfilterofanydebriswhich
mayhaveaccumulatedandreinsert
thefilterbackintothecoldwater
inlet.
3) Securelyscrewthefilterbackinto
place.Handtightenonly.
CHECKINGFORACROSSCONNECTION:
1) Turnoffcoldwatersupply.
2) Turnonallhotwaterfixtures.
a. Thewatershouldeventuallycompletelydrain.
b. Ifwatercontinuestorun,thefixturesandplumbingsystemneedstobechecked.
c. Coldwatercrossconnectionsmayberelatedtoarecirculationpumpapplication,a
badcheck
valve,ormissingcheckvalveintheapplication.
CHECKFOR REVERSE C ONNECTION:
1) Closecoldwatersupplyattheinlet.
2) Openthepressurereliefvalve;itshouldbeinstalledonthehotsideoutletoftheunit.
3) Ifwatercontinuestorun throughthepressurereliefvalve,thesystemhasareverse
connection.
Figure20