Specifications
TroubleshootingGuide
7|Page
GASLINE 
•  Incorrectgastype,NG(Natural)orLP(Propane),isoneofthemostcommonandsimple
problems.Verifythecorrectgastypeby:
o  Checkingthatthestampontheburnermanifoldmatchesthegastypesuppliedatthe
applicationsite.
o  Checkingtheboxthattheunitcomesin
forthegastype.
o  Minimumgaslinesizeforthetanklesswaterheateris¾inchpipe. Thesizecanbe
greaterdependingonthedistancetothegasmeterorregulator.
o  SizethepipetodeliverthemaximuminletBTU/hrforeachtanklesswaterheater.This
number
is199,000BTU/hourforasingle520(T‐H2),or180,000BTU/hourforasingle
320(T‐H2S).
•  Purgethegaslineofair.Seep.23forinstructions.Ifairispresentinthegaslinetheheaterwill
gooffwithanerrorcodeforlossofflame
[121]orignitionfailure[111].
•  Checkthegassupplypressures.SeetheSpecificationchartonp.1nexttotheTableofContents.
WATERLINE
•  Thetanklesswaterheaterrequiresa¾ inchconnectiontothecoldwaterinletandhotwater
outlet.
•  Tanklesswaterheatersallrequirea“Pressureonly”reliefvalve(PRV)oneachindividualunit
ratedfor150psiwithadischargecapacityofatleasttheratedgasinputof
thewaterheater
(199,000BTU/h)tobeinstalledperlocalcode.
•  Installa¾”CSA/AGAapprovedisolationvalveoneachheateronallthreeinlets(Hot,Cold,Gas)
fortroubleshootingandmaintenanceprocedures.
•  Re‐circulationsystems:
o  Minimumflowrateof2.0gpmthroughthesystem.
o  Air
separatorandairventinstalledinthesystem.
•  Ifsedimentisknowntobeinthewatersupply,aY‐strainermaybeneededtopre‐filter
contaminantspriortoenteringtheheater’scoldwaterinletscreen.
•  Forareaswithhardwater,installingawatersoftenerishighlyrecommended.
Heatexchanger
damageandfailureduetoscalebuildupcanhappenr apidlyandisnotcoveredbythewarranty.
POWERSUPPLY
•  Theunitshouldbeconnectedtoaproperlygrounded120VAC60Hzpowersupply.
•  Makesurethataproperdisconnect(i.e.on/offswitch,powerplug,etc.)controllingthemain
powertotheunitisinstalled.