Specifications

TroubleshootingGuide
7|Page
GASLINE
Incorrectgastype,NG(Natural)orLP(Propane),isoneofthemostcommonandsimple
problems.Verifythecorrectgastypeby:
o Checkingthatthestampontheburnermanifoldmatchesthegastypesuppliedatthe
applicationsite.
o Checkingtheboxthattheunitcomesin
forthegastype.
o Minimumgaslinesizeforthetanklesswaterheateris¾inchpipe. Thesizecanbe
greaterdependingonthedistancetothegasmeterorregulator.
o SizethepipetodeliverthemaximuminletBTU/hrforeachtanklesswaterheater.This
number
is199,000BTU/hourforasingle520(TH2),or180,000BTU/hourforasingle
320(TH2S).
Purgethegaslineofair.Seep.23forinstructions.Ifairispresentinthegaslinetheheaterwill
gooffwithanerrorcodeforlossofflame
[121]orignitionfailure[111].
Checkthegassupplypressures.SeetheSpecificationchartonp.1nexttotheTableofContents.
WATERLINE
Thetanklesswaterheaterrequiresa¾ inchconnectiontothecoldwaterinletandhotwater
outlet.
Tanklesswaterheatersallrequirea“Pressureonly”reliefvalve(PRV)oneachindividualunit
ratedfor150psiwithadischargecapacityofatleasttheratedgasinputof
thewaterheater
(199,000BTU/h)tobeinstalledperlocalcode.
Installa¾”CSA/AGAapprovedisolationvalveoneachheateronallthreeinlets(Hot,Cold,Gas)
fortroubleshootingandmaintenanceprocedures.
Recirculationsystems:
o Minimumflowrateof2.0gpmthroughthesystem.
o Air
separatorandairventinstalledinthesystem.
Ifsedimentisknowntobeinthewatersupply,aYstrainermaybeneededtoprefilter
contaminantspriortoenteringtheheater’scoldwaterinletscreen.
Forareaswithhardwater,installingawatersoftenerishighlyrecommended.
Heatexchanger
damageandfailureduetoscalebuildupcanhappenr apidlyandisnotcoveredbythewarranty.
POWERSUPPLY
Theunitshouldbeconnectedtoaproperlygrounded120VAC60Hzpowersupply.
Makesurethataproperdisconnect(i.e.on/offswitch,powerplug,etc.)controllingthemain
powertotheunitisinstalled.