Specifications
TroubleshootingGuide
16|Page
2)  Checkthegassupply.Verifythatsufficientgasisbeingsuppliedtotheheaterandthegaslineis
clearedofdebris.
a.  Itispossiblethereisafaultypressureregulatoratthegasmeter.
b.  Forpropaneunits,colderperiodsofthedayresultinacoldregulator
andmaycausethis
problem.
3)  Verifythatthegassupplypressureiswithin
specificationswhentheheaterisinstandbyand
whentheheaterisrunning.
4)  Checkthattheclearplastictubeconnectingthe
proportionalgasvalvetothecombustionchamber is 
attached.
5)  Iftheflamecomes
onfor1‐2secondsbutthengoes
out,cleantheflamesensor(p.27).
6)  Theoverheatcutofffusemayhavebeen
compromised.Forproceduresonhowtocheck
whethertheOHCFisintact,refertop.26.Ifithas,
contactthetechnicalservicedepartmentforfurther
assistance.
7)
  Checkforblockagesinventing,suchasbirdnests,animals,ortrash.
8)  PCBoardfaultorGasSolenoidfault.
a.  Ifoneoftheseissuspectedtobetheproblem,contactthetechnicalservicedepartment.
ERRORCODE311:OUTPUTTHERMISTOR
1)  Checkthatthewireconnectionsaresecureandfree
ofburnsorcuts.Theoutputthermistorislocatedon
theheatexchangerontherightside.
2)  Checktheresistancevalue;itshouldbeabout9.0kΩ
atroomtemperature(about74°F).
3)  Cleanthethermistor.
a.  Draintheunitofwater.Seep.23.
b.  Removethefastenerholdingtheoutput
thermistorandpulloutthesensorprobe.Clean
theprobetoasilverfinish.Do
notlosethe
rubbero‐ringthatwrapsaroundthissensor.
c.  Replaceandtest.
4)  Iftheerrorcodepersists,replacethethermistor.
ERRORCODE321:INLETTHERMISTOR
1)  Checkthatthewireconnectionsaresecureandfreeofburnsorcuts.Theinletthermistoris
embeddedinthewaterinletconnection.
2)  Checktheresistancevalue;itshouldbeabout9.0kΩatroomtemperature(about74°F).
3)  Cleanthethermistor.
a.  Draintheunitofwater.Seep.
23.
b.  Removethecomputerboardtoaccesstheinletthermistor.Thecomputerisfixedinplacebya
singlescrewatthetopoftheboard.
c.  Removethescrew,pulloutthesensorprobe.Cleantheprobetoasilverfinish.Donotlosethe
rubbero‐ring
thatwrapsaroundthissensor.
d.  Replaceandtest.
Figure10
Figure11