Specifications
TroubleshootingGuide
13|Page
5.3TROUBLESHOOTING‐ERRORCOD ES
• Allunitsareselfdiagnosticforsafetyandconveniencewhentroubleshooting.
• Ifthereis a problemwiththeinstallationortheunit,itwilldisplayanumericalerrorcode on
the TM‐RE30 Remote Controller (if installed) or on the 3‐digit 7‐Seg LED at the center
of the
computerboardtocommunicatethesourceoftheproblem.
• Consultthefollowingchartforthecauseofeacherrorcode.
SINGLEUNIT
• The3‐digit7‐SegLEDdisplayserrorcode,ortheTM‐RE30(ifinstalled)displaysthe3‐digiterrorcode.
EASY‐LINKSYSTEM
The7‐SegLEDoftheindividualunitwiththeerrorinquestiondisplaysthewhole3‐digiterrorcode.
TheTM‐RE30(ifinstalled)displaysa3‐digitnumberwhichsignifieswhichunithastheerror,andwhat
theerrorcodeis.
Table3–ErrorCodes
Error Symptom Error Symptom Error Symptom
031 IncorrectDipswitch
Settings
391 Air‐fuelRatioRodFailure 661 AbnormalWaterBypassValve
101 Warningfor991
ErrorCode
441 FlowSensor 701 ProportionalValve/
Computer
111 IgnitionFailure 510 AbnormalMainand
SolenoidGasValve
711 Hi‐Limitswitch/
OverheatCutoffFuse
121 FlameLoss 551 SolenoidValves 721 FalseFlameDetection
311 OutputThermistor 611 AbnormalFanMotor 741 RemoteController
CommunicationFailure
321 InletThermistor 621 ExhaustFanMotor
(Indoormodelsonly)
761 CommunicationFailure
(Easy‐Link)
331 MixingThermistor 631 ExternalPump 941 AbnormalExhaust
Temperature
341 ExhaustThermistor 651 AbnormalFlow
AdjustmentValve
991 Abnormalcombustion
7‐SegLED
Figure4
Figure5
–
TM‐RE30(Optional)