Specifications

TroubleshootingGuide
10|Page
Theflowadjustmentvalvecouldbeobstructedduetohardwaterscaleordebris,causinglower
thanexpectedwaterflow.Verifywaterflowwithagraduatedcontainerorwiththeremote
temperaturecontroller,ifoneisinstalled.
Theoutputthermistorcouldbecompromised.Thiscomponentmaybecheckedby
enteringthe
DiagnosticsModeonaremotecontroller,ifoneisinstalled.Turnpowerofftotheunit andrun
coldwaterthroughit;checktoseeiftheinletandoutlettemperaturesreadthesameonthe
remote.Forinstructionsonhowtodothis,refertotheMaintena nce
Sheet,packagedwith
everytanklesswaterheaterandlocatedbehindthefrontpaneloftheunit.
TEMPERATUREFLUCTUATESWH ENAFIXTUREISOPENED
MakesuretheunitisinstalledproperlyusingtheProperInstallationsection(p.6)ofthisguide.
Testwhethertheproblemiswithintheunitorexternaltotheunit(i.e.plumbingsystem)by
attemptingtorunhotwaterlocallythroughthePRV.
o Doestheheaterigniteand
remainrunningproperly?Ordoestheheatershutdowninto
anerrorcode?
Plumbingconnections
o Checkforacrossconnection(p.24).
o Problemswitharecirculationsystem:
Checkthatacheckvalveis installedbetweenthepumpdischargeandthe
connectiontothecoldwatersupply.
Checktoseeifthepumpisoperatingproperly.
Checkforaircavitation.Thepumpwillbeveryhotorchattering.
Checkthedirectional indicatoronthepumpflange.
Checkthesizingofthepumpaminimumflowof2gpmisrequired.
Checkgas
supply
o VerifythegassupplylinesaresizedforthemaximumBtu/hdemand,asindicatedinthe
ProperInstallationsection(p.6)ofthisguide.Ifthegassupplylineissharedwithother
appliances,itshouldbesizedtoaccountforthoseappliancesaswell.Theheaterwill
stilltrytorunifthegassupplyisundersizedandhasnowayofdirectlydeterminingif
thereisnotenoughgas.
o ForLPmodels,theremaynotbeenoughgasleftinthepropanetank.
o Verifythatthesupplygaspressureiswithinspecification,not onlywhen
theheaterisin
standby,butwhiletheheaterisrunningonmaximumfireaswell.
o Thegassupplypressuremaybetoolow.Thismaybecausedbyamalfunctioninggas
supplyregulator.
Venting
o Verifythattheexhaustventingisinstalledtomanufacturer’sspecification.
o Verify
thattheventrundoesnotexceedthemaximumlimit(50ft.)
Thefilteroncoldwaterinletshouldbeclean;lookforsignsofhardwaterscaling.
Ifthecleartubefromtheproportionalgasvalvetothebottomofthecombustionchamberis
disconnected,fluctuations intemperatureand/orverylowflowtothefixturesmayoccur.
Onwellsystemsorevenonsomecitywatersystems,waterpressurefluctuations(especiallyon
lowflow)of8to10psiwillresultinflowratefluctuations,whichwillinturnresultinminor
temperaturefluctuations.
Flowsensor
orwatercontrolvalvemaybecompromised.Contactthetechnicalservice
department.