Operating Instructions and Installation Instructions
Remote Display / Remote Display / Ecran de Contrôle Solaire
11
3.4 Contribution
screen
4. Errors
This screen displays the contribution of the solar system.
Actual = Current contribution of solarsystem (W)
Σ
24h
= Contribution in the last 24 hr (MJ)
Σ
tot
= Total contribution (GJ)
The Remote Display only has two failures,
1. No current supply to the Remote Display
When the Remote Display does not receive any current, the display will remain dark and
no text will appear on the screen. Check the following possible causes of the failure:
- wiring between the Remote Display and the solar system control
- connection of the wiring in the Remote Display.
- power supply to the solar system control
- power supply to the installation
2. No Remote Display communication
When the Remote Display does not detect any communication, the message given
below will appear on the display. Check the following possible causes of the failure:
- wiring between the Remote Display and the solar system control
- connection of the wiring in the Remote Display.