Operating Instructions and Installation Instructions
Remote Display / Remote Display / Ecran de Contrôle Solaire
10
3. Control
3.1 Main menu
3.2 Temperature
screen
3.3 Pumpscreen
When switching on, the SGE or SGS the
Remote Display will automatically be activated.
The Remote Display automatically detects to
which installation (SGE or SGS) it has been
connected. After the System Check, the
Remote Display goes to the main menu.
This main menu displays the installation and shows three data. First, the collector
temperature is shown to be followed by the tank temperature and the total contribution of the
solar system.
SGE
SGS
S
1
= Collector temperature(ºC)
S
2
= Tank temperature(ºC)
Σ
tot
= Total contribution (GJ)
You can use the DOWN button and the UP button to scroll through 3 status screens from
the main menu. Besides the main menu, the following screens are available:
1. Temperature screen
2. Pump screen
3. Contribution screen
This screen displays all temperatures measured in the solar system.
S
1
= Collector temperature (ºC)
S
2
= Tank temperature (ºC)
S
3
= Top Tank temperature (ºC) (only SGS)
S
4
= Temperature Q/T-sensor (ºC)
This screen displays the pump data.
M = Status pump (ON/OFF)
M = Pump speed (%)
Q = Flow Q/T-sensor (l/min)