User guide
Specifications 
3
Caution:  *Relief valve has been factory fit with the water heater and set at 0.8 MPa 
(8 Bar) rated pressure. 
Warning: Do not tamper or detach the safety valve from the water heater. 
Dimensions 
Model  A(mm)  A1(mm)  B(mm)  B1(mm)  C(mm) 
HSE-HNS-050 850  376 434 195  427 
HSE-HNS-060 717 305  483 230  483
HSE-HNS-080 876 405 483 230 483
Fig. 1
Model HSE-HNS HSE-HNS HSE-HNS
-050 -060 -080
Rated volume [L] 50 60 80
Rated AC voltage [V]/Rated frequency [Hz] ~220/50 ~220/50 ~220/50 
Rated input power
Quick power heating mode [W] 3000 3000 3000
Standard power heating mode [W] 3000/2000 3000/2000 3000/2000
Low power heating mode [W] 2000 2000 2000
Net weight [kg]  22 25 29
Reheating time for 35°C [3kW in min] 39 47 62
[2kW in min] 58 70 93
Temperature range [°C]  35-75 35-75 35-75
Rated water pressure  N/cm 80 80 80
Water head (metres) 80 80 80
Inlet/Outlet Connection [Inch] BSP ½ BSP ½ BSP ½
2
B1
B
C
Hot water (outlet) Cold water (inlet)
Relief valve*
A1
100
A
Quick 
Standard
Heat 
Modes
MAX
kWh
Hot Water
Quantity 
Override 
Energy
meter 
Timer3
0
C
:
88 88
Timer 2Timer 1Timer 3
MAX
Low
Timer ON
Timer OFF
0
C
Clock/
Timers 