Installation Guide

26
“AIR” IN HOT WATER FAUCETS
HYDROGEN GAS: Hydrogen gas can be produced in a hot water
system that has not been used for a long period of time (generally
two weeks or more). Hydrogen gas is extremely ammable and
explosive. To prevent the possibility of injury under these conditions,
we recommend the hot water faucet, located farthest away, be
opened for several minutes before any electrical appliances which are
connected to the hot water system are used (such as a dishwasher
or washing machine). If hydrogen gas is present, there will probably
be an unusual sound similar to air escaping through the pipe as the
hot water faucet is opened. There must be no smoking or open ame
near the faucet at the time it is open.
SAFETY SHUT OFF SYSTEM
This water heater is designed to automatically shut off in the event
of the following:
1. When the pilot flame is extinguished for any reason.
A thermocouple is used to determine if a pilot ame is present
and will shut off the gas supply to the main burner and pilot if
the ame is absent.
2. When the water temperature in the tank exceeds 18F (87°C).
The gas control valve\thermostat includes a temperature
limiting ECO (Energy Cut Off) system that activates when
excessive water temperatures are present. If this occurs, the
system cannot be reset. The gas control valve/thermostat
must be replaced.