Installation Instructions
Installation and Service Manual Epsilon-Series
34
OPEN
Openingairbox gure12.3.b
Removingcasing gure12.3.a
2
3
1
2
3
1
fanunitandgasvalve
gure12.3.c
gure12.3.d
10
12.3 Maintenance activities
Required tools:
- Cross head screwdriver
- T-handle key set with 3 bits (hex key 4mm, hex key 5mm and cross head PZ2)
- Open end wrench 8mm
To carry out the maintenance activities please follow the next procedure:
- Switch o the power supply;
- Remove the screw behind the door on the front of the casing (see g. 12.3.a);
- Lift the casing and remove it towards the front.
The air box
- Remove the transparant air box (see g. 12.3.b);
- Clean the box with a cloth with a simple (non-abrasive) cleaning agent;
The fan unit and burner cassette (see g. 12.3.c and 12.3.d)
- Remove the electrical connection plug from the gas valve (1) and fan motor (2);
- Loosen the nut (3) of the gas pipe under the gas valve;
- Replace the gasket with a new one;
- Loosen the front cross head screw (4) of the black plastic silencer;
- Turn the left (9) and right (10) clamp bars with the hex key a quarter turn and pull
these out in a forward motion. Note the correct turning direction (red indicator,
g. 12.3.e);
- Slightly lift the fan unit and remove it towards the front of the heat exchanger;
2
3
9
4
1