Technical Documents

Page 3 of 4
www.hotwater.com
AOSTT35200
Commercial Storage Tanks
STORAGE TANK SELECTION
TJH-200 THRU TJH-1000
FIGURE 2.
NOTE: Inspection openings, i.e., handholes and manholes, are optional and are to be included with glasslined tanks only when specified.
Tanks so equipped are f.o.b. Seattle.
Other tanks to 66” diameter and 3500 gallon are available on special order.
All openings Female Pipe Thread except as noted.
OPTIONAL
4”x6” handhole or 11”x 15” manhole on vessels 36” in diameter or less.
Additional openings
D D
H H
C
F
2"
E-NPT E-NPT
E-NPT
E-NPT
J
PLUG
E
I
I*
I*
3/4" NPT
1" NPT
3/4" NPT
A
G
B
E-NPT
MODEL AND
GALLON CAPACITY
A B C D E F G H
“I” ASME
Inspection
Openings
J
TJH-200 41 36 77 16 2 1/2 11 23 16 2” 1 1/2
TJH-250 41 36 90 15 2 1/2 11 23 22 1/2 2” 1 1/2
TJH-350 47 42 93 17 1/2 2 1/2 10 26 22 1/2 2” 1 1/2
TJH-400 47 42 99 17 1/2 2 1/2 10 26 26 2” 1 1/2
TJHT-500 53 48 94 21 3 11 29 19 1/2 12” X 16” 1 1/2
TJH-500 59 54 79 22 3/4 3 12 32 11 12” X 16” 1 1/2
TJH-750 59 54 111 22 3/4 3 12 32 27 12” X 16” 1 1/2
TJH-1000 59 54 143 22 3/4 3 11 32 43 12” X 16” 1 1/2
*Note: These connections are not for piping
connections. They are the anode locations and also
serve as the required ASME 2” inspection openings.
AOSTT35200 R Sept 2013 TJV TJH Spec Sheet.indd 3 9/25/13 2:28 PM