Technical information
30
Servicing should only be performed by a Qualied Service Technician
TEST 9 – IGNITER HEATS – NO MAIN BURNER
TEST 9 IGNITER HEATS – NO MAIN BURNER
IF......... THEN............
Meter reads 0 or 1. • Check meter scale setting to read between 550 and 650 Ohms.
• Replace Gas Valve.
Meter indicates pilot and main coil
have continuity.
Valve should be okay, still no gas to main burner, then coil may be
stuck. Replace Gas Valve.
CONDITIONS:
• Test 8 completed then:
• Turn off power.
• Disconnect wires from gas valve.