Technical information

28
Servicing should only be performed by a Qualied Service Technician
TEST 7 INDUCER ON PROVER SWITCH AND LOW GAS SWITCH CLOSED.
NO IGNITER OPERATION
TEST 7 Voltage check and continuity check of hot surface igniter
circuit
Continuity check - Power off- Plug removed from E4
receptacles.
Nominal 80 VAC check - Plug in E4- Power "On".
IF......... THEN............
Continuity is not indicated
between E4 plug pin 2 to 4.
Check wiring and connection from E4 plug to HSI receiving plug.
Replace HSI Assembly.
Continuity is present. Resistance should be between 11 and 20 Ohms at a temperature of
77°F.
Voltage is not present between
E4, Pin 2 to ground.
Replace ignition board.
Voltage is present. Continue.
Voltage is not present between
E4, Pin 4 to ground.
Check wiring and plug connections to HSI. Replace HSI.
Voltage is present. Note ignition board, Flash code LED. HSI should work.
CONDITIONS:
Power On.
Plugs in Receptacles.
Inducer ON.
24V at ignition board E1, Pin 10.
No power to Igniter.