Technical information
28
Servicing should only be performed by a Qualied Service Technician
TEST 7 – INDUCER ON – PROVER SWITCH AND LOW GAS SWITCH CLOSED. 
NO IGNITER OPERATION
TEST 7 Voltage check and continuity check of hot surface igniter 
circuit
Continuity check - Power off- Plug removed from E4 
receptacles.
Nominal 80 VAC check - Plug in E4- Power "On".
IF......... THEN............
Continuity is not indicated 
between E4 plug pin 2 to 4.
Check wiring and connection from E4 plug to HSI receiving plug. 
Replace HSI Assembly.
Continuity is present. Resistance should be between 11 and 20 Ohms at a temperature of 
77°F.
Voltage is not present between 
E4, Pin 2 to ground.
Replace ignition board.
Voltage is present. Continue.
Voltage is not present between 
E4, Pin 4 to ground.
Check wiring and plug connections to HSI. Replace HSI.
Voltage is present. Note ignition board, Flash code LED. HSI should work.
CONDITIONS:
•  Power On.
•  Plugs in Receptacles.
•  Inducer ON.
•  24V at ignition board E1, Pin 10.
•  No power to Igniter.