ATI-C Installation Manual
43 Page
Troubleshoong
Owner's Guide
Remote
Green
LED
Malfunction
description
Diagnosis
651*
Four Times
Flow adjustment
valve fault (Only
Easy-Link & Multi-Unit
System)
• Inspect the flow adjustment valve (Part #402), for
connection/breakage of wires, locked motor drive due to
scale buildup, and/or water leakage.
661*
Four Times
Bypass valve fault
(510C model only)
• Inspect the bypass valve (Part #403), for connection/
breakage of wires, locked motor drive due to scale
buildup, and/or water leakage.
701*
One Time
Computer board fault
• Check for connection/breakage of wires (Part #713).
711*
One Time
Gas solenoid valve
drive circuit failure
• Refer to the 111 and 121 error codes.
721*
Six Times
False flame detection • Check if condensate drain is installed on the vent collar of
the water heater.
• Check if there is leaking from heat exchanger (Part #401).
741
N/A
Miscommunication
between water heater
and remote controller
• Check the model type of the remote controller.
• Inspect the connections between the water heater and
remote controller.
• Check the power supply of the water heater.
751
N/A Miscommunication
between water
heater and built-in
controller
• Inspect the connections between the water heater
and built-in controller.
• Check the power supply of the water heater.
761
N/A
Miscommunication in
Easy-Link system
• Check if the connections between the parent unit and the
child units are correct. Refer to p. 25.
991
Five Times
Imperfect
combustion
• Check the gas type of the water heater.
• Inspect the environment around the water heater.
Determine how long the unit has been installed.
• Check the altitude/elevation of the area of where the
water heater is installed.
• Check if there is any blockage in the intake air and/or
exhaust.
• Check whether there is enough distance between the
concentric terminals.
• Check if there is grease and/or dirt in the burner (Part
#101) and the fan motor (Part #103), especially if the
water heater has been installed in a contaminated area.
*These error codes will be cleared when water flow stops.