ATI-C Installation Manual
4 Page
Model
110C 310C 510C
Natural Gas Input
(Operating Range)
BTU/h
Min.: 15,000
Max.: 140,000
Min.: 15,000
Max.: 190,000
Min.: 15,000
Max.: 199,000
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure*
psi
(Mpa)
15 - 150 (0.1 - 1)
Natural gas
Inlet Pressure
" W.C.
(kPa)
Min. 5.0 (1.24)
Max. 10.5 (2.61)
Weight lbs. (kg) 51 (23)
Dimensions
inch
H 20.5 x W 13.7 x D 10.5
H 520 x W 350 x D 266
mm
Ignition Electric Ignition
Electric
Supply VAC / Hz 120 / 60
Consumption
Operation W / A 53 / 0.58 71 / 0.81 72 / 0.85
Standby W / A 2 / 0.06 2 / 0.06 3 / 0.07
Freeze-
Protection
W / A 99 / 0.83 99 / 0.83 100 / 0.83
SPECIFICATIONS
*Maximum flow may need water pressure equal to or above 40 psi.
NOTE:
• Checktheratingplatetoensurethisproductmatchesyourspecifications.
• InaccordancewithANSIZ21.10.3,COemissiondoesnotexceed400PPMfornormalinput.
• The manufacturer reserves the right to discontinue, or change at any time, specifications or designs
without notice and without incurring obligations.
Specicaons
Installaon Manual