9. Turn on power to the “PARENT unit.
Next, turn on “CHILD-1”. When the built-in controller installed in “CHILD-1” unit displays a number,
turn on “CHILD-2”.
When the built-in controller installed in the “CHILD-2” unit displays a number, turn on “CHILD-3”.
Make sure the built-in controller installed in each child unit displays each unit #. (Refer to p.40.) The
numbering system automatically allocates the unit No. to each water heater in the Easy-Link System,
in accordance with the table below.
10. Set the water temperature using the built-in temperature controller on the “PARENT” unit. It will set
the temperature for the Easy-Link System. If a remote controller is installed to the “PARENT heater,
it will override the built-in controller.
(A) 510C model Computer board
(B) Diagram of connections between the Easy-Link System units
Type of unit Unit # of easy-link
Parent 1
Child 2, 3, or 4
NOTE: The dark squares indicate the direction the DIP switches should be set to.
PARENT
Communicaon cable
Connectors
Lower bank of
DIPswitches
OFF
ON
1
1
1
12
2
2
2
PARENT
PARENT
PARENT
1
2
3
4
5
6
Connectors Connectors Connectors
1
2
3
4
5
6
OFF
ON
OFF
ON
1
2
3
4
5
6
OFF
ON
1
2
3
4
5
6
Lower bank of
DIPswitches
Lower bank of
DIPswitches
Lower bank of
DIPswitches
PARENT unit
CHILD-1 unit CHILD-3 unit
CHILD-2 unit
Remote controller
To change the DIP switch
settings for the Easy-Link
System, locate the bank of
DIP switches at the bottom
left of the computer board.
Do not adjust the upper
bank of DIP switches.
Easy-Link /
Mul-Unit
connectors
are next to
the computer
board.
Lower bank of DIP switches
Upper bank of DIP switches
Installaon
Installaon Manual
Connecting two “PARENT connectors together from two separate units may
damage the computer board. The communication cable has a female end and
a male end so its impossible to have a PARENT-to-PARENT connection with the
communication cable. Do not splice or modify connectors.
WARNING