Installation Guide
NEED HELP? GIVE US A CALL 855.424.9892 NEED HELP? GIVE US A CALL 855.424.9892
INSTALLATION GUIDE
2
13
12
Flush Lines
1 Place water softener in Bypass position. 
Turn on main water supply.
2 Turn on nearest cold water faucet to flush 
plumbing of any excess soldering flux, 
air, or any other foreign material. Return 
water softener to Service position. 
7
8
9
Check for Leaks
Plug in the Transformer
Turn off all faucets. Check all lines and 
connections for leaks. 
If leaks are found:
• Turn off the main water supply.
• Turn on cold water faucet to depressurize 
the lines.
• Turn off the faucet to eliminate any 
siphoning action.
• Repair all leaks.
• Turn on the water supply.
• Place bypass in Service position to slowly 
fill media tank. (see image)
• Turn on cold water faucet to purge air out 
of media tank.
• Turn off the faucet and recheck for leaks.
1 Ensure the sensor wire and motor wire 
are connected, then plug the transformer 
power cord to the back of the controller. 
(see Connecting Power)
2 Plug the transformer into an appropriate 
outlet. Ensure the outlet selected is not 
operated by an On/Off switch.
3 Program the water softener controller in 
the next step.
Connect Drain Line
Connect Gravity Overflow 
Connection
The overflow line drains away excess water 
should the cabinet overfill or the water 
softener malfunction. (see Gravity Overflow 
Elbow) Ensure the overflow elbow is in the 
down position.
The drain line carries away backwash water 
as part of the regeneration cycle.
1 Connect drain line to drain end cap (see 
Connect Drain Line) with a minimum 
1/2" (1.27 cm) I.D. tubing (supplied). This 
size cannot be reduced. Note: Using PTFE 
tape or plumber’s putty, screw threaded 
drain fitting into drain end cap.
2 Route drain line to a floor drain, laundry 
tub, or other suitable waste receptacle. 
Maintain a minimum 2" (5 cm) air gap 
between drain line and flood level rim 
of waste receptacle to prevent back 
siphoning. This drain line should be the 
shortest distance to the suitable drain.
3 Drain line may be elevated up to 8' 
(2.4 m) from the discharge on the water 
softener if water pressure in your system 
is 40 psi (2.8 bar) or more.
4 If drain line is 25 feet (7.6 m) or longer, 
increase drain line to 3/4" I.D. The end of 
drain line must be equal to or lower in 
height than the control valve.
5
6
Connect 1/2" (1.27 cm) I.D. tubing (size 
cannot be reduced) between the overflow 
fitting and a floor drain, laundry tub, or 
other suitable waste receptacle. Note: 
This tubing is not supplied with the water 
softener. Ensure the overflow line ends 
at a drain that is at least 3" (8 cm) lower 
than the bottom of the overflow fitting. 
Maintain a minimum 2" (5 cm) air gap 
between the overflow line and the flood 
level rim of the waste receptor to prevent 
back-siphoning. The gravity line cannot be 
run overhead.
Connect Drain Line
NOTICE: Keep the drain line from being 
kinked, crimped, or restricted in any way.
NOTICE: Drain line may require a hose clamp 
to hold drain line in place. 
Connecting Power
INSTALLATION
NOTICE: To prevent untreated water from 
entering your home, avoid using water inside 
your home when water softener is in Bypass 
position. Remember to return to Service 
position when you have finished flushing the 
system or using untreated water.
Gravity Overflow Elbow
Bypass Position
Service Position