Installation Guide
NEED HELP? GIVE US A CALL 855.424.9892 NEED HELP? GIVE US A CALL 855.424.9892
INSTALLATION GUIDE
2
9
8
The Bypass Valve can isolate the appliance 
should appliance malfunction or leak. It 
can also permit the use of untreated water 
for watering plants, shrubs, or lawns.
The Bypass Valve is attached to the main 
control valve. To engage the Bypass Valve, 
locate the gray knob on top of the Bypass 
Valve. Turn knob to the left until it hits the 
stop. The appliance will be bypassed and 
all water to the home is raw, untreated 
water. To prevent untreated water 
from entering the home, water should 
not be used inside the home when the 
appliance is in Bypass Mode. Ensure that 
the appliance is returned to Service Mode 
when the appliance is repaired or the 
use of untreated water is complete by 
turning the gray knob to the right until it 
hits the stop.
GETTING TO KNOW YOUR NEW SOFTENER VALVE OVERVIEW
Bypass Position
Service Position
1
1
2
3
4
6
5
8
2
3
6
7
4
5
9
10
Part
1
Brine Cabinet
2
Media Tank
3
Drain Line 
4
Bypass Valve
5
Bypass Position
6
Bypass Knob
7
Service Position
8
Safety Shutoff
9
Controller
10
Brine Line
Part
1
Bypass Valve
2
Gravity Flow 
Connection
3
Brine Cabinet 
4
Lid
5
Drain Line Fitting
6
Controller 
Housing