S T Use this owner’s manual to reference installation, troubleshooting and filter replacement information. If you need help or have a question, we've got you covered. (el 0T TiE -1 877.333.
Xe Smith. A. O. Smith has obsessively engineered this filtration system for you. This product, combined with an A. O. Smith filter. creates an effective filtration method that reduces rust, soil and silt for improved, better tasting water throughout your entire home. Keep this owner’s manual to reference installation, troubleshooting and filter replacement information. If you need help or have a question, weave got you covered. Give us a call at 877.333.7108.
BOX CONTENTS FILTER HEAD HOUSING WRENCH CLEAR HOUSING TIMER MOUNTING BRACKET Please read enter manual to ensure all parts listed are present before Installation. If any part is missing or damaged let us know by calling 877.333.7108. Do not attempt to install the filter.
PRECAUTIONS READ ALL PRECAUTIONS AND INSTALLATION INSTRUCTIONS CAREFULLY. Before installing: ‘When installing: » Do not install this filtration system » Properly tighten all fittings to ensure a where the line pressure may exceed leak-free assembly. 100 psi. The operating pressure range for this filtration system is between * Be sure to sweat any fittings away 25 psi 100 psi. from filter housing. * Install on cold water lines only * Allow a minimum of clear space {40* 100°F).
n Turn off main water supply. n Remove clear housing from filter Drain water from water lines. head and set aside. B Wrap Teflon® tape (2-12 wraps} to the right around the 1" male x 1" street adapter. Screw firmly to filter head. (See Figure 1) FIGURE 1 Do not use pipe solvent (dope), as solvents in some types of pipe dope may cause damage to plastic fittings. Do not over-tighten to prevent damage to filter head. n Loosely fit shut-off valves on both sides to calculate proper spacing of components.
4 INSTALLATION GUIDE B ‘When installing on metallic plumbing, ensure you take the following precautions: Securely install two (2) grounding clamps and a #4 copper wire across the location where the system will be installed. Tightly clamp at both ends, as shown below. (See Figure 3) COPPER WIRE ELECTRICAL SHOCK HAZARD re reg g iy BBR 9 copra Lie o plow sk fictions GROUND GROUND CLAMP CLAMP FIGURE 3 fl Cut pipe to length with pipe cutter. Ensure there are no burrs, sharp edges or deep scratches.
n Place a filter {purchased separately) into clear housing. Ensure filter is centered and seated Screw housing with filter into head. Hand tighten until snug If necessary, tighten with supplied filter wrench to seal properly. DO NOT OVER-TIGHTEN. depressing red air release button (on filter head}. Check for leaks. Allow water to run for five (5) minutes to flush out air.
5 CARE AND MAINTENANCE Water leaks at fittings: The following range of A. O. Smith Slowly tighten until leak stops. filters can be used with this housing Water leaks persist: Turn off water at the main water supply shut-off valve. Remove threaded fittings. AQ-WH-PRELRP Reapply Teflon® tape to the right and screw fittings back onto head assembly. AQ-WH-PREL-RCP CLEANING The exterior of your filtration system can be cleaned with warm, soapy water. Rinse well with fresh, clean water.
LIMITED WARRANTY What Is covered: How to get service: This Warranty covers defects in materials To receive service under this or workmanship In manufacturing of your ~ Warranty, you must contact A. O. Smith Whole House Sediment Filter, except as provided below. For how long: This warranty runs for 12 months from the date of purchase by a consumer (*Warranty Period").
Xe Mitos. A. O. imite diseñé este sistema de filtración minuciosamente para usted. Este producto, combinado con un filtro de A. O. Mitos, crea un método eficaz de filtración que reduce el oxido, |a tierra y el sedimento, lo que mejora el agua su sabor en toda la casa. Conserve este manual del propietario como referencia para la instalación, resolución de problemas e información de cambio del filtro.
CONTENIDO DE LA CAÍA 3 CABEZAL DEL FILTRO LLAVE PARA LA CARCASA TEMPORIZADOR ‘CARCASA TRANSPARENTE SOPORTE DE MONTAJE Lea todo el manual antes de la instalad para asegurarse de que todas las piezas indicadas estén presentes.
10 PRECAUCIONES LEA DETENIDAMENTE TODAS LAS PRECAUCIONES Y LAS INSTRUCCIONES DE INSTALACIÓN. Antes de la Instalación: * No instale este sistema de filtración donde |a presión de |a tubería pueda superar los 689 kPa (100 psi). El rango de presión de funcionamiento para este sistema de filtración es entre 172 kPa y €89 kPa (25 psi y 100 psi). * Instale solo en tuberías de agua fría a 100 * Proteja la unidad del congelamiento.
12 Gula DE INSTALARON n Cierre el suministro principal de agua. n Retire |a carcasa transparente el Drene el agua de las tuberías de agua. cabezal del filtro y déjela a un lado. B Coloque cinta Teflon® (2-1/2 vueltas) hacia la derecha alrededor del adaptador 1" macho x 1* macho-hembra. Atornille firmemente al cabezal del filtro.
14 Gula DE INSTALARON n Coloque el cabezal del filtro y las válvulas de cierre de entrada en la tubería. Asegúrese de que el puerto “IN* {Entrada) con el botan de liberación de aire rojo esté conectado a la Linea de suministro de agua entrante. Apriete las tuercas de compresión de las cuatro (4} ubicaciones a ambos lados de cada válvula.
15 INSTALACIÓN Y CAMBIO DE LA BATERÍA DEL TEMPORIZADOR Inserte un curio o destornillador en la ranura entre |a tapa del temporizador y la base. Abra cuidadosamente y separe |a tapa del temporizador de la base. Instale o cambie dos {2) baterías nuevas AAA de 1.5 voltios. Alinee la base y la tapa y vuelva a juntaras. Se recomienda cambiar |as baterías al menos cada dos (2) cambios de filtro. No mezcle baterías viejas y nuevas.
16 CUIDADO Y MANTENIMIENTO RESOLUCIÓN DE PROBLEMAS Hay fugas de agua en los conectores: Apriete lentamente hasta que se detenga la fuga. Las fugas de agua persisten: Cierre el suministro de agua de |a válvula de cierre del suministro de agua principal Retire los conectores roscados. Vuelva a colocar cinta Teflon® hacia la derecha coloque nuevamente los conectores en el conjunto del cabezal. LIMPIEZA Puede limpiar el exterior de su sistema de filtración con agua tibia con jaén.
GARANTÍA LIMITADA Lo que ésta cubierto: Esta garantía cubre defectos en materiales o &n la mano de obra de la fabricada de su filtro de sedimentos para toda la casa de A. O. Mitos, salvo seg din se estipula a continuación. Duración: Esta garantía dura 12 meses a partir de la fecha de compra por parte del consumidor (“Periodo de garantieran.