Specifications

TroubleshootingGuide
8|Page
5.2TROUBLESHOOTING‐GENERALPROBLEMS
ProceedtotheErrorCodessectionifanerrorcodeisidentified.Forothercommonproblemsthatdo
notinvolveanerrorcode,seeifthefollowingitemshelp:
Thewaterisnothotenough.
Thewateristoohot.
Temperaturefluctuateswhenafixtureisopened.
Unitdoesnotignitewhenwatergoesthroughit.
Ittakesalongtimetogethotwateratthefixtures.
Thefanmotorisstillspinningafteroperationhasstopped.
Abnormalsoundscomefromtheunit.
Lossofpressureatallsinkswhenthedishwasher
fills.
Unithaspower,gas,andwaterbutdoesnotturnon.
MultipleHeaterSetup(EasyLink)
THEWATERISNOTHOTENOUGH
Comparetheflowandtemperatureatthepressurereliefvalve.
o IfthetemperatureandflowratearecorrectatthePRVthentheproblemresidesinthe
plumbingline,notinthetanklessunit.Checkforacrossconnectionorotherwaterline
problems
Testthehotwater
temperaturewithahandheldthermometertomeasurehowfaroffthewater
temperatureisfromthesettemperature.
o Thesettemperaturemaybesettoolow.Thetemperaturecanbechangedwiththe
pushbuttonsonthePCBorbytheremotetemperaturecontroller,ifoneisinstalled.
Check
forcrossplumbingbetweencoldwaterlinesandhotwaterlines.SeetheProcedures
section(p.21)forinstructions.
Unitmaybehardwaterscaled.Thescaleactsasaninsulatorpreventingtheheatexchanger
fromtransferringheattothewater.ContactaTakagiServiceAgent.
Theunitmay
notbereceivingenoughgas.
o Thegassupplyvalvemaynotbefullyopen.
o Thegaslinemaybesizedimproperly.
o Thegassupplypressuremaybetoolow.Thismay becausedbyamalfunctioninggas
supplyregulator,sochecktoseeifyourregulatoris
workingproperly.
Checktoseethatacheckvalveisinstalledbetweenthepumpdischargeandtheconnectionto
thecoldwatersupply.Inspectthecheckvalveforproperoperation.Ifthereisn’toneinstalled,
orifitismalfunctioning,coldwatermaybebackfeedingintothesystem.
Doublecheckfora101errorcode.A101errorcodewillreducetheamountofgasinputinto
theheater.
Outputtemperaturewillbeaffectedifairflowisimpeded.
o Checkconstructiondustanddebrisinventing,suchasdrywall.
o Ifthereisdustinside
thecabinet,therewillalsobedustinsidetheburnerandheat
exchanger.Seetheprocedureforcleaningtheburner(p.26).
THEWATERISTOOHOT
Thesettemperaturemaybesettoohigh.Thetemperaturecanbechangedwithdipswitcheson
thePCBorbytheremotetemperaturecontroller,ifoneisinstalled.