5.4TROUBLESHOOTING‐PROCEDURES
VerifyingproperDipswitchsettings…p.19
Drainingtheunit………………………………p.21
Cleaningthefilter…………………………….p.21
CheckingforaCrossConnection………p.21
CheckforReverseConnection………….p.21
Checkgassupplypressure……………….p.21
Purgethegaslineofair…………………..p.22
Adjustingmanifoldpressure…………….p.22
Resettingthecomputerboard…………p.23
CheckingtheOHCF………………………….p.24
VERIFYINGPROPERDIPSWITCHSETTINGS:
IncorrectDipswitchsettingscancausea031errorcode,oranumberofoperationalproblems.
Table3310(TK4),110(TKJr2)DipswitchSettings
No. Function ONposition OFFposition
1 Gastype Propane Disable
2 NaturalGas Disable
3 FM+,FM++,FM+++110Indoor(TKJr2IN),310Indoor(TK4IN)
No.3
OF position Nposition
No.4 OFFposition 0% +6%
ONposition +12% +18%
110Outdoor(TKJr2OS),310Outdoor(TK4OS)
No.3
OFFposition ONposition
No.4 OFFposition 0% +4%
ONposition +8% +12%

4
5 N/A N/A N/A(Default)
6 Modeltype Outdoor110(TKJr2OS),
Outdoor310(TK4OS)
Indoor110(TKJr2IN),
Indoor310(TK4IN)
7 Outputtemperaturesettings(Default122F)
8