Specifications

TroubleshootingGuide
18|Page
ERRORCODE721[510(TD2)],SIXFLASHES/72[110(TKJR2),310(TK4)]
FALSEFLAMEDETEC TION
1) Firstandforemost,shutoffallgasandpowertotheunit.Theproblemcouldbetheflamesensor,
butifitisn’t,thisisaverydangeroussituation.
2) ContacttheTechnicalServiceDepartmentforfurtherassistance.
ERRORCODE741[510(TD2)],74[110(TKJR2),310(TK4) ]
MAINREMOTECONTROLPROBLEM
Thiserrorcodeonlyoccurswhenthereisamiscommunicationbetweenthetemperatureremote
controllerandthewaterheater.
1) Checkthatallwiringisproperlyconnectedtotheremote.
2) Verifythecorrectmodelofremoteisbeingusedforthecorrespondingtanklessmodel.
3) Verifythatonlyaremote
isinstalled.Multipleremoteswillresultinthiserrorcode.
4) Ifyoudisconnecttheremotefromtheheaterwiththepowersupplyon,thiserrorcodewillresult.
Turnoffpowerbeforedisconnectingtheremotefromtheheater.
5) Checkforanysignsofpowersurges.
ERRORCODE761[510(TD2)]
COMMUNICATIONFAILURE
1) Thiserrorcodeonlyoccursinamultipleheatersetup,wherethereisamiscommunicationbetween
masterandslaveunitsforEasyLinksystems.
2) Thiserrorcodewillonlybedisplayedonthemasterheater.
3) Thiserrorindicatesthatthemasterunithaslostcommunicationwiththeindicated
heater.
4) Verifythatthereispowertotheunitthathaslostcommunication.
5) SeetheInstallationManualforpropercommunicationcablesetup.
6) Checkforsignsofpowersurges.
ERRORCODE991[510(TD2)],FIVEFLASHES/99[110(TKJR2),310(TK4)]
ABNORMALCOMBUSTION
1) Refertoerrorcode101.
2) ContacttheTechnicalServiceDepartmentforfurtherassistanceifnothinghasworkedsofar.The
manifoldgaspressuremayneedadjustment.
3) Ifyouaresurethattheproblemhasbeensolved,resetthecomputer(p.23).