Specifications

TroubleshootingGuide
16|Page
ERRORCODE391[510(TD2)],TWOFLASHES/39[110(TKJR2),310(TK4) ]
AIRFUELRATIORODFAILURE
1) Checkthatthewireconnectionsaresecureandfreeof
burnsorcuts.
2) Checkthattheclearplastictubeconnectingthe
proportionalgasvalvetothecombustionchamber is
attached.
3) CleantheAFR(p.25).
ERRORCODE441[510(TD2)]
FLOWSENSOR
PartofanEasyLinksystem(510(TD2)only),themasterunit
signaledforanadditionalheatertoactivateanditdidnot.
1) Verifythatwaterisbeingsuppliedtotheheaterinerror.
2) Verifythatthewiresareconnectedtothecomputerboard.
3) Checktheinlet
filterforanydebris.Seep.21.
4) Checktheflowsensorfordebris.
ERRORCODE510[510(TD2)],SIXFLASHES/51[110(T
KJR2),310(TK4) ]
ABNORMALGASVALVES
Drivingcircuitfaultforthemainorsolenoidgasvalves.
1) Ifthehotwaterisshutoff,butflames
arestillvisiblethroughthesightglass,
immediatelyshutoffgasandpowerto
theunitandcontacttheTechnical
ServiceDepartment.
2) Checkthewireconnectionstothegas
valve
assemblyforburnsorcuts.
3) Iftheunitwasrecentlyrebuilt,make
surethateachgasvalvewireisplugged
intotheproperplace.
4) Verifythatthesupplygaspressureis
withinthespecifiedlimits.Toohighof
aninletgaspressuremaycausethe
maingasvalvetojamorcouldbe
damaged.
ERRORCODESIXFLASHES/55[110(TKJR2),310(TK4)]
ABNORMALSOLE NOIDGASVALVE
Drivingcircuitfaultforthesolenoidgasvalve.
1) Ifthehotwaterisshutoff,butflamesarestillvisiblethroughtheburnersightwindow,immediately
shutoffgasandpowertotheunitandcontacttheTechnicalServiceDepartment.
2) Checkthewireconnectionstothegasvalveassembly
forburnsorcuts.
3) Iftheunitwasrecentlyrebuilt,makesurethateachgasvalvewireispluggedintotheproperplace.
4) Verifythatthesupplygaspressureiswithinthespecifiedlimits.Toohighofaninletgaspressure
maycausethemaingasvalvetojamorcouldbe
damaged.
Figure10
Figure11
Figure12