Specifications

TroubleshootingGuide
12|Page
TMRE30(Optional)
5.3TROUBLESHOOTING‐ERRORCOD ES
Allunitsareselfdiagnosticforsafetyandconveniencewhentroubleshooting.
Ifthereisa problemwiththe installation ortheunit,itwilldisplaya numerical errorcode on
the Remote Controller (if installed), on the 7Seg LED on the computer board (510 (TD2)), or
theflashingredLED(110(TKJr2),310(TK4))tocommunicatethesourceoftheproblem.
Consultthefollowingchartforthecauseofeacherrorcode.
Table2ErrorCodes
ErrorCode
510(TD2)
7SegLED,
remote
ErrorCode
110(T
KJr2),310
(TK4)
Remote
ErrorCode
RedLED
110(TKJr2),
310(TK4)
MalfunctionDescription
031 03 1 IncorrectDipswitchSettings
101 10 5 Warningfor991ErrorCode
111 11 3 IgnitionFailure
121 12 3 FlameLoss
311 31 2 OutputThermistor
321 32 2 InletThermistor
331 N/A N/A MixingThermistor
391 39 2 AirfuelRatioRodFailure
441 N/A N/A FlowSensor(EasyLinkSystemonly)
510 51 6 AbnormalGasValves
N/A 55 6 AbnormalSolenoidGasValve
611 61 4 AbnormalFanMotor
651 N/A N/A AbnormalFlowAdjustmentValve(EasyLinkSystemonly)
701 70 1 ComputerBoardFault
721 72 6 FalseFlameDetection
741 74 N/A RemoteControllerCommunicationFailure
761 N/A N/A CommunicationFailure(EasyLinkSystemonly)
991 99 5 Abnormalcombustion
Errorcodeon
theTKRE02
Errorcodeonthe
computerboard
RedLED
Errorcodeon
theTMRE30
Errorcodeonthe
computerboard
7SegLED
Figure4
310(TK4),110(TKJr2)ErrorCodeoutputs
Figure5
510(TD2)ErrorCodeoutputs