Specifications

64
stcudorP retaW htimS .O .A Service Workbook
Ashland City, Tennessee 2005© Training Department
TROUBLESHOOTING ERROR CODES
Error Code "210" - Indicates Central Processing Unit (CPU) Fault
Display window will show "LOCO 210"
The CPU, located on the Central Control Board, has a non-repairable fault. Replace the
CCB.
Miscellaneous Information
1. These units require a proper hot (voltage supply), "clean" neutral and proper grounding
to operate correctly, to minimize the risk of electrical problems, it is recommended that
wiring to this appliance be isolated from wiring to other appliances.
2. Shipping may loosen wiring connections to plugs or terminals.
3. Under certain conditions, low or not gas pressure can result in a "00_" communication
error code.
4. Loose or broken receptacles on the CCB or an ICB can result in a "00_" communication
error code.