A. O. Smith Water Products Service Handbook
Ashland City, Tennessee 2005
©
Training Department
TROUBLESHOOTING ERROR CODES
Error Code "08" Stage 1, 2, 3, or 4 - This indicates Igniter Failure
On Display Board red light is on "Ignitor Fail" Red LED for indicated Stage - On
Display Window will show "LOCO 08".
This is an electrical feedback from the HSI.
Power is "ON" - Plugs are in receptacles
Ignition Control Board
Terminal Boards (strips)
located inside bottom of
Control Box
Lockout
Status
If error code is then
Hard
igniter did not receive 120V or did not stay on. The igniter did not
meet the minimum threshold amps of 2.7 to continue(approximately)
23 seconds Pre-"trial for ignition" time
81
check connection to ICB CN5 of Stage indicated to igniter.
082
perform continuity check - (40 - 70 Ohms, igniter cold) Check
resistance on igniter.
084
check for 120 VAC to neutral on TB 4 Terminal 1 to ICB CN1, Pin 1
(if not 120V,
check F1 fuse)
084
replace igniter.
replace board or correct wiring as indicated.
"08?" indicates Igniter Failure. The last number in the code is the Stage (Ex. 081 = Stage 1)