Specifications
55
A. O. Smith Water Products Service Handbook
Ashland City, Tennessee 2005
©
Training Department
TROUBLESHOOTING ERROR CODES
Error Code "060" - This indicates Blocked Flue
On Display Board red light is on "Blocked Flue" Red indicates LED - On
Display Window will show "LOCO 060".
Blocked Flue Switch has opened (.60 + pressure to open). Switch is located to the left of the
vent and rear of the cabinet - near air intake opening.
Power is "ON" - Plugs are in receptacles
Central Control Board
Terminal Board 2
CN 14
Lockout
Status
If error code is …
… then
•
•
•
•
opens at .60 positive pressure
check vent equivalent length
check for blockage
replace switch
if closed, 24 VAC should be present at TB2, Terminal 20 and 21
Both Terminal to Ground
check wiring and 24 VAC from TB2 Terminal to CCB CN14, Pin 9.
check wiring and 24 VAC supply from CN 14 Pin 1 to TB2 Terminal
20. Pin one is actually only sent to one termina
l then jumped across
to the others.
"060" indicates Insufficient Blocked Flue.
060Soft