Specifications
12
stcudorP retaW htimS .O .A Service Workbook
Ashland City, Tennessee 2005© Training Department
DIRECT VENT - VERTICAL (CATEGORY I)
DIRECT VENT (VERTICAL EXHAUST CONFIGURATIONS)
APPLIANCE CERTIFIED EXHAUST VENT MAXIMUM AIR INTAKE AIR INLET MAXIMUM
MODEL CATEGORY EXHAUST VENT SIZE EXHAUST VENT MATERIAL SIZE AIR INTAKE
MATERIAL (IN) LENGTH (FT) (IN) LENGTH (FT)
GAL. STEEL
RO SBA ,CVPI
CPVC
GAL.STEEL
RC SBA ,CVPI
CPVC
GAL. STEEL
RO SBA ,CVPI
CPVC
GAL. STEEL
RO SBA ,CVPI
CPVC
GAL. STEEL
RO SBA ,CVPI
CPVC
TYPE B OR
EQUIVALENT
TYPE B OR
EQUIVALENT
TYPE B OR
EQUIVALENT
TYPE B OR
EQUIVALENT
TYPE B OR
EQUIVALENT
10"
(25.4 cm)
12"
(30.5 cm)
14"
(35.6 cm)
14"
(35.6 cm)
16"
(40.6 cm)
35'
(10.7 m)
35'
(10.7 m)
20'
(6.1 m)
20'
(6.1 m)
20'
(6.1 m)
35'
(10.7 m)
35'
(10.7 m)
20'
(6.1 m)
20'
(6.1 m)
20'
(6.1 m)
8"
(20.3 cm)
10"
(25.4 cm)
10"
(25.4 cm)
12"
(30.5 cm)
12"
(30.5 cm)
• The vent should be installed so as to prevent the accumulation of condensate and, where necessary, have means
provided for drainage of condensate. The horizontal breaching of a vent must have an upward slope of not less than
1/4 inch per linear foot (2 cm/m) from the boiler to the vent terminal. The horizontal portion of the vent shall be
supported to maintain clearances and to prevent physical damage or separation of joints.
I000
1300
1500
1850
2100
2500