Instruction manual
19
RS-232 COMMANDS
RS-232 Communication Commands
With this command system, users are able to control and operate theANI-MOD with RS-232 software remotely.
Communication protocol: Baud rate: 9600; Data bit: 8; Stop bit: 1; Parity bit: none.
Command Types Command Codes Functions
/*Type; Inquire the models information.
/%Lock; Lock the keyboard of the control panel on the Matrix.
/%Unlock; Unlock the keyboard of the control panel on the Matrix.
/^Version; Inquire the version of rmware
/:MessageOff; Turn off the feedback command from the com port. It will only show the “switcher OK”.
/:MessageOn; Turn on the feedback command from the com port.
Undo. To cancel the previous operation.
Demo. Switch to the “demo” mode, 1>1, 2>2, 3>3 … and so on.
[x]All. Transfer signals from the input channel [x] to all output channels
All#. Transfer all input signals to the corresponding output channels respectively.
All$. Switch off all the output channels.
[x]#. Transfer signals from the input channel [x] to the output channel [x].
[x]$. Switch off the output channel [x].
All@. Switch on all the output.
[x]@. Switch on output [x].
[x1]V[x2]. Transfer the video signals from the input channel [x1] to the output channel [x2].
[x1]A[x2]. Transfer the audio signals from the input channel [x1] to the output channel [x2].
[x1]B[x2]. Transfer signal from the input channel [x1] to the output channel [x2].
Status[x]. Inquire the input channel to the output channel [x].
Status. Inquire the input channel to the output channels one by one.
Save[Y]. Save the present operation to the preset command [Y]. [Y] ranges from 0 to 9.
Recall[Y]. Recall the preset command [Y].
Clear[Y]. Clear the preset command [Y].
PWON. Work normally.
PWOFF. Enter in standby mode.
HDCPON. Turn on the HDCP output.
HDCPOFF. Turn off the HDCP output.
/V00. Inquire the version of backboard software.
UpgradeIntEDID[x]. Upgrade built-in EDID data. Supports 6 types of EDID data (see Note 6). When the
switcher gets the command, it will show a message to send EDID le (.bin le).
EDIDUpgrade[x]. Upgrade EDID data of input ports. When the switcher gets the command, it will show a
message to send EDID le (.bin le). Operations will be canceled after 10 seconds.
EDID/[x]/[y]. Set the EDID data of input port [x] to built-in EDID data of type [y].
The value of [y] varies from 1~6. The EDID data types are same as mentioned above.
EDIDG[x]. Get EDID data from output channel X and display the data on serial port control
software. [x] is the output port number.
EDIDMInit. Recover the factory default EDID data for every input channel.
EDIDM[X]B[Y]. Manually EDID switching. Enable input [Y] to learn the EDID data of output[X]. If there is
problem learning the EDID data, it will automatically set the default EDID data for input [Y].
USER/[Y]/[X]:*****; Custom command for signal cards, [Y]=I/O; [X]= port number; *****: User-denable
command, e.g. 0623%
0911%. Restore factory default. All I/O connection will be restored to straight through: 1>1,
2>2,…; saved operation status will remain the same.
A NEUVIDEO
Commands for Main Unit