- FOR LPG -
4. Turn the LOW IDLE switch (Fig. 8 ) to “OFF”.
1. Turn the FUEL SOURCE switch (Fig. 11) to the “LPG” position.
8. Place one hand on the generator to hold it in place,
and pull on the recoil starter handle slowly until a slight
resistance is felt (Fig. 11). Then pull quickly to start the engine.
Return cord gently into the machine. Never allow the cord
to snap back.
2. Connect the LPG gas hose to the propane fuel source (Fig. 12).
3. Connect the small end of the LPG gas hose to the LPG regulator on the
generator and then snug with a wrench to prevent leakage (Fig. 13).
6. Rotate the LPG valve to open the LPG (Fig. 14).
Fig. 12
Fig. 11
Fig. 13
Fig. 14
5. Turn the MAIN switch (Fig. 8 ) to the “ON” position.
7.With the choke at "RUN" (Fig. 10), press and hold the
pressure-reducing valve button to store air for 3.5 seconds.