3 10887 Commerce Way Unit A Fontana CA 92337
Model SUA2000iD 1600W-GAS / 1500W-LPG 2000W-GAS / 1800W-LPG 7 2 48.4 lbs SAE 10W-30 Product Dimension: L x W x H 19.7×11.4×18.3inch Packing Dimension: L x W x H 21.7×13.0×20.
DUE TO THE FAILURE OF FOLLOWING
identified If there are any questions concerning
an enclosed
product
SUA2000iD Torch E5T
1 2 3 4 10 5 9 8 7 1. MAIN 2. LOW IDLE Turn ON to increase fuel economy and runtime when the load is below 75% load 3. DC 5V USB Outlets (1.5A) 6 6. Parallel Operation Outlets Connect two AIPOWER inverter generators through a parallel connection kit for a higher output 7. Grounding Nut Ground generator to reduce risk of electric shock 4. Low Oil Alarm Overload Alarm Output Indicator 8. CHOKE 5. FUEL SOURCE switch 10. AC 120V Receptacle (20A) 9.
LOW IDLE LOW IDLE OFF
( refer to part 3.4 in this manual for how to start).
Connect the Parallel Cables first, then start the greater wattage unit first if different from the other. Sockets (Please refer to 4.4 for how to connect properly) . Fuel Selector Switch The Fuel Selector Switch controls the desired fuel source. When switch is turned left, gasoline is selected. When switch is truned right, LPG is selected and hose inlet is exposed for hook up.
greater w attag e ,
1.1GAL.
3.4.1 1. Turn the FUEL SOURCE switch (Fig. 7) to the “GAS” position. 2. Turn the LOW IDLE switch (Fig. 8) to “OFF”. 3. Turn the MAIN switch (Fig. 8) to the “ON” position. Fig. 7 4. While holding the fuel tank cap so that it will not move turn the air vent knob to “ON” (Fig. 9) 5. Pull the CHOKE LEVER (Fig. 10) out to the “START” position. (NOTE: Skip this if starting the generator with a warm engine.) Fig. 8 6.
- FOR LPG - 1. Turn the FUEL SOURCE switch (Fig. 11) to the “LPG” position. 2. Connect the LPG gas hose to the propane fuel source (Fig. 12). Fig. 11 3. Connect the small end of the LPG gas hose to the LPG regulator on the generator and then snug with a wrench to prevent leakage (Fig. 13). 4. Turn the LOW IDLE switch (Fig. 8 ) to “OFF”. Fig. 12 5. Turn the MAIN switch (Fig. 8 ) to the “ON” position. 6. Rotate the LPG valve to open the LPG (Fig. 14). 7.With the choke at "RUN" (Fig.
MAIN 1. Turn the MAIN switch (Fig. 12) to the “OFF” position.
1 2
G s Performance Allows you to increase the output by connecting two generators together. By using the parallel connection wires provided. SUA2000iD Attention: Be sure generators are powered off and without load when connecting the parallel wires.
connected.
Refer to the "Starting" section of the manual not connected cause damage. properly, 4.The outlets now can be used. ⑤ ③ A-IPOWER A-IPOWER Make sure to connect the correct parallel wire into the correct socket. Connect the parallel wires when generator is off. Parallel wires are not necessary when only one generator is being used.
LOW IDLE Connect the Negative (Black) cable first. Then connect the Positive (Red) cable. Do not reverse these cables and take care as to not let the cables touch eachother or other items.
SUA2000iD Torch E5T
NOTE: Never operate the engine without foam element.
generator 1 2 3 4 5. Remove the dipstick and drain the engine oil.Then tighten the dipstick. 6. 7. 8.
Please call our customer service @ 1-855-888-3598 for help.
A-iPOWER WARRANTY REGISTRATION FORM Register your product by mailing this form to support@a-ipower.com or register online at www.a-ipower.com. Registering your product is important, it provides protection: 1) You have record of product purchased. 2) Customer Service can Better serve you for Warranty related issues. 3) We can contact you in the unlikely event should notification is necessary. 4) Alway keep copy of your orginal receipt.