Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death or serious injury.
WARNING
4. Turn cylinder valve to the OFF position.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1. DO NOT try to restart the engine.
2. Contact an Authorized Service Dealer.
3. DO NOT operate engine until oil level is corrected.
If oil level is below LOW mark on dipstick:
1. Add oil to bring level to HIGH mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist. DO NOT try to restart
the engine.
3. Contact Customer Service.
4. DO NOT operate engine until oil level is corrected.
NOTE:
If the engine will not be used for a period of two
weeks or longer, please see the Storage section for
proper engine and fuel storage.
Do Not Overload Generator
Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and to
connected electrical devices.
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Changing Fuels
DANGER
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
DANGER
DO NOT add gasoline to the gasoline tank or connect
the Propane/LPG hose to the generator while the
generator is running.
5. Turn off the battery switch to “OFF”(O) position .
FUEL SENSE (Automatic Fuel Selection Technology)
Your generator is equipped with FUEL SENSE technol-
ogy which automatically switches fuel intake between
gasoline and propane/LPG to extend runtime. Propane
is a prioritized fuel which means the generator will use
propane as soon as the Propane Cylinder Valve is
opened. The generator will use gasoline if there is not
enough propane remaining in the cylinder OR if the
Propane Cylinder Valve is closed.