PORTABLE GENERATOR Owner’s Manual GXS4300iD DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT Model: Serial: Date Purchased: P/N: 32082-00000-00 Model# 1492006 REV00 SAVE THIS MANUAL FOR FUTURE REFERENCE
Table of Contents Introduction..........................................1 Stopping the Engine..............................22 Safety....................................................1 Low Oil Shutdown................................22 General Safety Precautions....................2 Do Not Overload Generator....................22 Unpacking the Generator.......................8 Changing Fuels.....................................23 Parts Included........................................
INTRODUCTION Read This Manual Thoroughly WARNING Read and understand manual completely before using product. Failure to completely understand manual and product couldresult in death or serious injury. If any section of this manual is not understood, contact customer Service at 855-888-3598, or www.a-ipower.com for starting, operating and servicing procedures. The owner is responsible for proper maintenance and safe use of the unit. SAVE THESE INSTRUCTIONS for future reference.
Asphyxiation Hazard Electric Shock Hazard Fire Hazard Explosion Hazard Hot Surface. Do Not Touch the Surface. Burn Hazard Moving Parts Hazard Kickback Operator’s Manual GENERAL SAFETY PRECAUTIONS Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors and vents. Avoid other generator hazards.
CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces.
WARNING Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury. • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback. • NEVER start or stop engine with electrical devices plugged in and turned on. FUEL SAFETY DANGER Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive.
• Store Fuel in a container approved for gasoline. • Store any containers containing gasoline or propane/LPG outdoor in a well-ventilated area, away from any combustibles or source of ignition. DANGER Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Never use a gasoline container, gasoline tank, propane/LPG connector hose, propane/LPG cylinder or any other fuel item that is broken, cut, torn or damaged. Failure to do so will result in death and serious injury.
WARNING WARNING Starter and other rotating parts could entangle hands, hair, clothing, or accessories. Keep away from rotating parts, failure to do so could result in death or serious injury. Exhaust heat/gases could ignite combustibles, structures or damage fuel tank causing a fire, resulting in death or serious injury. Contact with muffler area could cause burns resulting in serious injury. • DO NOT wear loose clothing, jewelry or anything that could be caught in the starter or other rotating parts.
• Shut off generator if: -Electrical output is lost. -Equipment sparks, smokes, or emits flames. -Unit vibrates excessively. WARNING Medical and Life Support Uses. • In case of emergency, call 911 immediately. • NEVER use this product to power life support devices or life support appliances. • NEVER use this product to power medical devices or medical appliances. • Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live.
UNPACKING THE GENERATOR • Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items. • Call our customer service at 855-888-3598 with the unit model and serial number for any missing item. • Record model, serial number, and date of purchase on front cover of this munual for your own record. 1 Parts Included Your gasoline powered generator ships with the following parts: 2 4 NO.
CONTROLS AND FEATURES 1 6 2 3 7 89 4 5 10 1 - Recoil Starter 7 - Telescopic Handle 2 - Control Panel 8 - Panel LED Light 3 - Fuel Cap 9 - Propane Inlet 4 - Maintenance Cover 10 - Support Leg 5 - Carrying Handle 11 - Muffler/Spark Arrester 6 - Wheel Page 09 11
CONTROL PANEL FEATURES 1 11 2 10 9 3 4 8 1. LED DATA CENTER: See LED DATA CENTER section. 2. CO (Carbon Monoxide) WATCH-GUARD Indicator Light (Red for Shut off and Yellow for Service): The CO(Carbon Monoxide) WATCH-GUARD monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running. If the CO WATCH-GUARD detects increasing levels of CO gas, it automatically shuts off the engine. See CO WATCH-GUARD section for more information.
CONTROL PANEL FEATURES LED Data Center 1 2 3 4 1. LED Multi-Meter: Displays voltage,power,fuel level, frequency, and running time. 2. Low Idle Push Button: Low idle minimizes the fuel consumption and noise by adjusting the engine speed to the minimum required for the current load. 3. Low Oil Indicator LED(Red): Illuminates when the engine oil level falls below the safe operating level and the generator will automatically shut off the engine.
SPECIFICATIONS GXS4300iD Model Number 1492006 Starting Watts 4300W-GAS / 3900W-Propane/LPG Running Watts 3450W-GAS / 3100W-Propane/LPG Rated AC Voltage 120V Rated DC Voltage 12V Rated Frequency 60HZ Phase Single Grounding System (AC) Engine Type Neutral Floating Single Cylinder, 4-Stroke OHV Air Cooled Engine Displacement 149cc Starting System Recoil Low Oil Shutdown Oil Type Oil Capacity Spark Plug OEM Type Spark Plug Replacement Type Spark Plug Gap Yes 10W-30 16.2 fl.oz (0.
CO WATCH-GUARD Carbon Monoxide (CO) Detection and Auto Shutoff System Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and safety. This detecting and shutoff system monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running. If the CO sensor detects increasing levels of CO gas, it automatically shuts off the engine.
2-Blinking Yellow Light provides notification that a CO WATCH-GUARD fault has occurred and no longer provides protection. The generator is shutoff automatically and the yellow light will blink for at least five minutes after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings.
Add Engine Oil We recommend using SAE 10W-30 APISJ oil for best performance. Other high-quality detergent oils (APISJ or higher) are acceptable. Do not use special additives. Ambient temperature determines the proper oil viscosity for the engine. Use the chart to select the proper oil for the outdoor temperature range expected. NOTICE The unit is equipped with a low oil shutdown. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine.
B A 1. Remove the gasoline cap (A) slowly. 2. Slowly add unleaded gasoline to gasoline tank. Be careful not to fill above the red fuel level indicator (B). This allows adequate space for fuel expansion. 3. Install gasoline cap and let any spilled fuel evaporate before starting engine or wipe the spilled gasoline. WHEN ADDING GASOLINE • Only fill the gasoline tank outdoors in a well-ventilated area. • DO NOT overfill gasoline tank. Allow space for fuel expansion.
4. Open valve on propane LPG cylinder and check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. If a leak exists at a fitting, then turn off the valve on the cylinder and tighten the fitting. Turn the valve back on and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting, then do not use the generator and contact customer service.
Operation at High Altitude At altitudes over 5,000 feet(1524 meters), a minimum 85 octane gasoline is acceptable. Engine power and generator output will be reduced approximately 3.5% for every 1000 feet (305 m) of elevation above sea level. High altitude may cause hard starting, increased fuel consumption and spark plug fouling. To operate at high altitudes A-iPower can provide a high altitude carburetor main jet.
OPERATION Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short-duration voltage fluctuations. Generator Location WARNING Make sure you review each warning in order to prevent fire hazard. Before Starting the Generator Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open.
Select the Fuel Source (Propane/LPG) 2. Add gasoline to the fuel tank. 1. Connect the LPG gas hose to the propane fuel source. Connect the small end of the LPG gas hose to the LPG inlet on generator and then snug with a wrench to prevent leakage. 3. Turn the starting dial switch to the START position. 2. Fully open the Propane/LPG cylinder knob. Note: For restarting a warm engine, turn the starting dial switch directly to the “RUN” position. 4.
5. Turn the starting dial switch to the RUN position. NOTE: When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle. Do not apply heavy electrical load during break-in period (the first five hours of operations). 6. Pull recoil starter slowly until resistance is felt, then pull rapidly. 1. Let engine stabilize and warm up for a few minutes after starting. 2.
Turn LOW IDLE Switch to OFF position when powering large surge loads such as an air conditioner or electric pump. Be certain that the OUTPUT READY INDICATOR LED is illuminated green before turning the switch to ON position. If no load is present, the generator speed (RPM) will drop to idle speed. The generator will detect loads as they are applied and increase engine speed (RPM). To run the generator at maximum power and speed (RPM), push the LOW IDLE Switch to the OFF position. Stopping the Engine 1.
Changing Fuels 2a. Gasoline to Propane/LPG DANGER Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Fire or explosion can cause severe burns or death. 2a1. Connect the LPG gas hose to the propane fuel source. Connect the small end of the LPG gas hose to the LPG inlet on generator and then snug with a wrench to prevent leakage. DANGER DO NOT add gasoline to the gasoline tank or connect the Propane/LPG hose to the generator while the generator is running. 2a2.
3. Make sure the low idle switch is in OFF position on both generators. NOTICE Paralleling this generator to a generator that is not compatible can cause a low voltage output that can damage tools and appliances powered by the generator. Do not connect or disconnect parallel cables while the generator is running to avoid damage. Parallel operation gives you the ability to link this generator to a compatible AIPOWER generator for combined running and starting power output.
MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE Regular Maintenance will improve the performance and extend the life of your generator. Follow maintenance schedule intervals whichever occurs first according to use. NOTE: Adverse conditions will require more frequent services. NOTE: Maintenance should be performed more frequently when generator is used in dusty areas.
Recommended Engine Oil Type CAUTION 10W-30 5W-30 10W-40 5W-30 Full Synthetic ° F -20 °C -28.9 0 -17.8 20 -6.7 40 4.4 60 15.6 80 26.7 100 37.8 120 48.9 Ambient temperature Check the engine oil level before each use or every 8 hours of operation. 1. Place the generator on a level surface and allow the engine to cool for several minutes. 2. Loosen the bolts and remove the oil access cover. 3. With a damp rag, clean around the oil dipstick. 4. Remove the oil dipstick. 5.
6. Measure plug gap. The correct gap is 0.028-0.031 in. (0.7-0.8 mm). To widen gap, if necessary, carefully bend the ground (top) electrode. To lessen gap, gently tap ground electrode on a hard surface. 7. Seat spark plug in position; thread in by hand to prevent cross-threading. 8. Tighten with wrench to compress washer. If spark plug is new, use 1/2 turn to compress washer appropriate amount. If reusing old spark plug, use 1/8 to 1/4 turn for proper washer compression.
Short Term Storage Fill the tank with fresh gasoline and add gasoline stabilizer. Drain the carburetor float bowl. 1 - Add a properly formulated FUEL STABILIZER to the tank if it is not already added. 2 - Run the engine for 10-15 minutes to circulate stabilizer throughout fuel system. 3 - Allow the generator to cool a minimum of 30 minutes and then drain the carburetor float bowl. 4 - Clean the generator and store in a cool, dry and well ventilated area out of direct sunlight.
DRAINING THE FLOAT BOWL 1. Turn the fuel tank valve to the OFF position. 2. Locate the drain screw on the bottom of the carburetor float bowl. 3. Place an appropriate gasoline container to catch the drained fuel. 4. Loosen the float bowl drain screw and allow the fuel to drain from the drain tube. Tighten the float bowl drain screw. DANGER Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Store fuel in a well ventilated area. Keep fire and spark away.
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine is running, but no AC output is available. 1. AC Circuit breaker is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 5. GFCI outlet is open (if equipped) 1. Check AC load and reset circuit breaker. 2. Contact customer service or authorized service center. 3. Check and repair. 4. Connect another device that is in good condition. 5. Correct ground fault and press reset button on GFCI outlet.
1 2 3 59 4 11 10 9 8 12 55 13 14 22 18 19 20 21 15 41 42 43 44 45 46 47 48 49 16 23 40 24 25 17 39 38 26 27 28 37 29 36 53 52 51 50 43 30 35 10 31 32 34 1 8 1 10 33 54 1 Page 31 7 56 63 6 5 58 57 61 GXS4300iD PARTS DIAGRAM AND PARTS LIST PARTS DIAGRAM 60 62
Parts List NO. Part Number Description Qty. NO. Part Number Description Qty. 1 30111-00083-00 Philips screw M5*14 24 39 33004-01223-00 Engine mounting bracket 1 2 30111-00008-00 Philips screw M5*10 5 40 30101-00349-00 Hex flange bolt M6*40 2 3 30111-00023-00 Philips screw M4*12 1 41 34024-00085-00 Clip nut M6 6 4 31026-00388-00 Switch knob 1 42 33089-00511-00 Base plate 1 5 20114-07145-00 Panel assy.
Page 33 ENGINE Trigger Stepping motor ALTERNATOR Main coil Sub coil DC coil GND Low oil shutdown module(sensor) B Br R/W B L L LP OR Y B R CO sensor module O BL R W Control module B Br R/W Ignition coil Y B B B DC voltage regulator rectifier W W L L Grounding system(AC): Neutral Floating CIRCUIT DIAGRAM 9A GND O L B R W L/W Br B/W W B O L G G/W G/W B/W B/W R Gy - W Br Y L/W G/W G B B/W + Display module 20A W Fuel level sensor CO indicator light (Red light
WARRANTY LIMITED WARRANTY KEEP YOUR RECEIPT. Proof of purchase will be required to substantiate any warranty claim. WHAT IS COVERED: A-iPower Corp.
WARRANTY other force majeure events beyond the control of the manufacturer. Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied. This warranty gives you specific legal rights which vary from state to state.
Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.
A-iPOWER WARRANTY REGISTRATION FORM Register your product by emailing this form to support@a-ipower.com or register on-line at: www.a-ipower.com. Registering your product is important , it provides the following protections: 1. You have record of product purchased 2. Customer Service can Better serve you for Warranty related issues 3.
Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.