PORTABLE GENERATOR Owner’s Manual GXS11300RT DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT Model: Serial: Date Purchased: P/N: 32082-05737-01 Model# 4592016 REV00 SAVE THIS MANUAL FOR FUTURE REFERENCE
Table of Contents Introduction..........................................1 Connecting Electrical Loads..................23 Safety....................................................1 Stopping the Engine (Generator)............23 General Safety Precautions....................2 Low Oil Shutdown................................24 Unpacking the Generator.......................8 Do Not Overload Generator....................24 Parts Included........................................8 Changing Fuels..........
INTRODUCTION Read This Manual Thoroughly WARNING Read and understand manual completely before using product. Failure to completely understand manual and product couldresult in death or serious injury. If any section of this manual is not understood, contact customer Service at 855-888-3598, or www.a-ipower.com for starting, operating and servicing procedures. The owner is responsible for proper maintenance and safe use of the unit. SAVE THESE INSTRUCTIONS for future reference.
Asphyxiation Hazard Electric Shock Hazard Fire Hazard Explosion Hazard Hot Surface. Do Not Touch the Surface. Burn Hazard Moving Parts Hazard Kickback Operator’s Manual GENERAL SAFETY PRECAUTIONS Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors and vents. Avoid other generator hazards.
CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • Operate generators outside and at least 20 feet away from any structure with exhaust pointed away from doors and windows.
WARNING Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury. • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback. • NEVER start or stop engine with electrical devices plugged in and turned on. Fuel Safety DANGER Gasoline, gasoline vapor, propane/LPG and NG are highly flammable and explosive.
• Store Fuel in a container approved for gasoline. • Store any containers containing gasoline or propane/LPG outdoor in a well-ventilated area, away from any combustibles or source of ignition. DANGER DANGER Gasoline, gasoline vapor, propane/LPG and NG are highly flammable and explosive. Never use a gasoline container, gasoline tank, LPG/NG connector hose, propane/LPG cylinder or any other fuel item that is broken, cut, torn or damaged. Failure to do so will result in death and serious injury.
WARNING WARNING Starter and other rotating parts could entangle hands, hair, clothing, or accessories. Keep away from rotating parts, failure to do so could result in death or serious injury. Exhaust heat/gases could ignite combustibles, structures or damage fuel tank causing a fire, resulting in death or serious injury. Contact with muffler area could cause burns resulting in serious injury. • DO NOT wear loose clothing, jewelry or anything that could be caught in the starter or other rotating parts.
• Shut off generator if: -Electrical output is lost. -Equipment sparks, smokes, or emits flames. -Unit vibrates excessively. WARNING Medical and Life Support Uses. • In case of emergency, call 911 immediately. • NEVER use this product to power life support devices or life support appliances. • NEVER use this product to power medical devices or medical appliances. • Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live.
UNPACKING THE GENERATOR • Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items. • Call our customer service at 855-888-3598 with the unit model and serial number for any missing item. • Record model, serial number, and date of purchase on front cover of this munal for your own record. Parts Included Your gasoline powered generator ships with the following parts: NO.
4 - Secure everything with cotter pin (F), then assemble Cap(A) to Wheel(C). Repeat on opposite side. F D E NOTICE The generator is equipped with a battery charging feauture. Once the engine is running,a small charge will slowly recharge the battery. If you do not plan to use the generator for a long period of time,we recommend to DISCONNECT the battery plugs A and B to protect the battery from losing charge,You may also to use a battery float charger (not included) to maintain battery charge.
CONTROLS AND FEATURES 1 23 4 11 12 13 14 5 6 15 7 16 8 17 9 10 18 19 20 21 1 - Frame 12 - Recoil Starter 2 - LPG/NG Selector Switch 13 - Engine 3 - Main Fuel Selector Switch 14 - LPG/NG Inlet 4 - Fuel Cap 15 - Battery 5 - Control Panel 16 - Support Leg 6- Remote Holder 17 - Muffler/Spark Arrester 7 - Alternator Cover 18 - Carbon Canister 8 - Fuel Tank 19 - Wheel 9 - Fuel Gauge 20 - LPG Hose with Regulator 10 - Spark Plug 21- Hose Holder 11 - Air Filter Page 10
CONTROL PANEL FEATURES 1 2 3 4 5 6 7 8 9 8 10 12V 15 14 13 12 8 8 11 8 8 16 17 18 1. Push-Button START/STOP: Push once to automatically start the engine. Push again to stop the engine. 8. Circuit Breaker(AC): Protects the generator against electrical overloads. 2.
SPECIFICATIONS GXS11300RT Model Starting Watts (Gas) Running Watts (Gas) Starting Watts (Propane/LPG) Running Watts (Propane/LPG) Starting Watts (NG) Running Watts (NG) Rated AC Voltage Rated DC Voltage Rated Frequency Phase Grounding System (AC) Engine Type Engine Displacement Starting System Low Oil Shutdown Oil Type Oil Capacity Spark Plug OEM Type Spark Plug Replacement Type Spark Plug Gap Valve Intake Clearance Valve Exhaust Clearance Natural Gas (NG) pressure range Voltage Regulation System 4592016 1
Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F(6°C) above 60°F( 16°C) ambient temperature. CO WATCH-GUARD Carbon Monoxide (CO) Detection and Auto Shutoff System Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and safety.
sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings. WARNING DO NOT modify or tamper with the Carbon Monoxide Detecting System (CO WATCH-GUARD). Not following these instructions could result in death or serious injury due to Carbon Monoxide detecting system malfunction. CO WATCH-GUARD will detect the accumulation of carbon monoxide from other fuel burning sources such as engine powered tools used in the area of operation.
Add Engine Oil We recommend using SAE 10W-30 APISJ oil for best performance. Other high-quality detergent oils (APISJ or higher) are acceptable. Do not use special additives. Ambient temperature determines the proper oil viscosity for the engine. Use the chart to select the proper oil for the outdoor temperature range expected. NOTICE The unit is equipped with a low oil shutdown. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine.
A B 1. Remove the gasoline cap (A) slowly. 2. Slowly add unleaded gasoline to gasoline tank. Be careful not to fill above the red fuel level indicator (B). This allows adequate space for fuel expansion. 3. Install gasoline cap and let any spilled fuel evaporate before starting engine or wipe the spilled gasoline. • It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage.
5 . Open valve on propane LPG cylinder and check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. If a leak exists at a fitting, then turn off the valve on the cylinder and tighten the fitting. Turn the valve back on and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting, then do not use the generator and contact customer service.
apply to the intended use of the generator. Consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. This generator is not intended to be used at a construction site or similar activity as defined by NFPA 70-2020 (NEC) section 590.6. • If you smell gas, close off all gas sources and contact a qualified plumber for inspection and repair.
OPERATION Generator Location Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short-duration voltage fluctuations. WARNING Make sure you review each warning in order to prevent fire hazard. Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open.
5. Remote start Turn and hold the REMOTE START switch for 5 seconds until the engine start. Starting the Engine (Generator) Select the Fuel Source (Gasoline) 1. Make the propane tank is fully closed. Fully close the NG cylinder valve. Remote 5. Electric start Turn and hold the ENGINE START/STOP switch for 5 seconds until the engine start. Close 2. Add gasoline to the fuel tank. Electric 5. Recoil start Move the choke lever to the “START” position. 3. Turn the battery switch to the “ON”(l) position.
Select the Fuel Source (Propane/LPG) 1. Connect the LPG gas hose to the propane fuel source. 2. Fully open the Propane/LPG cylinder knob. 5. Turn the LPG / NG selector switch to LPG position. 6. Remote start Turn and hold the REMOTE START switch for 5 seconds until the engine start. Remote 3. Turn the battery switch to the “ON”(l) position. 6. Electric start Turn and hold the ENGINE START/STOP switch for 5 seconds until the engine start. Electric 4.
6. Recoil start Move the choke lever to the “START” position. 3. Connect the fuel supply line to the LPG/NG connector. Pull recoil starter slowly until resistance is felt, then pull rapidly. 4. Fully open the NG cylinder valve Move the chock lever to the “RUN” position. Open Recoil Select the Fuel Source (NG) 1. Turn the main fuel selector switch knob to the position. 5. Remote start Turn and hold the REMOTE START switch for 5 seconds until the engine start. Remote 2.
5. Recoil start Move the choke lever to the “START” position. Pull recoil starter slowly until resistance is felt, then pull rapidly. Move the chock lever to the “RUN” position. is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Re-adjusting will void warranty. NOTE: When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.
DANGER 2. Push STOP on the remote start key fob for 3 seconds. Push and hold the START/STOP button for 3 seconds. 3. Turn off the battery switch to “OFF” position. 4. Make the propane tank is fully closed. Fully close the NG cylinder valve. Close Gasoline, gasoline vapor, propane/LPG and NG are highly flammable and explosive. Fire or explosion can cause severe burns or death. NOTE: DO NOT stop the engine by moving choke control to “START” position.
Gasoline to propane/LPG Changing Fuels DANGER 3. Fully open the Propane/LPG cylinder knob. Gasoline, gasoline vapor propane/LPG and NG are highly flammable and explosive. Fire or explosion can cause severe burns or death. DANGER 3. Turn the main fuel selector switch knob to the position. DO NOT add gasoline to the gasoline tank or connect LPG/NG hose to the generator while the generator is running. 1.Disconnect all electrical loads from the generator. 3.
3. Turn the main fuel selector switch knob to the position. 3. Turn the main fuel selector switch knob to the gasoline position. 3. Turn the LPG / NG selector switch to NG position. 4. Start the engine (generator). See the “Starting the Engine (Generator)” section for starting procedure. NG/LPG to Gasoline 3. Make certain the propane tank is fully closed. 3. Fully close the NG cylinder valve.
MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE Regular Maintenance will improve the performance and extend the life of your generator. Follow maintenance schedule intervals whichever occurs first according to use. NOTE: Adverse conditions will require more frequent services. Walk-Around Inspection Before starting the engine perform a visual inspection of the unit.
Recommended Engine Oil Type CAUTION 10W-30 5W-30 10W-40 5W-30 Full Synthetic ° F -20 ° C -28.9 0 -17.8 20 -6.7 40 60 4.4 15.6 Ambient temperature 80 26.7 100 37.8 120 48.9 Check the engine oil level before each use or every 8 hours of operation. 1. Place the generator on a level surface and allow the engine to cool for several minutes. 2. With a damp rag, clean around the oil dipstick. 3. Remove the oil dipstick (A). 4. Wipe the dipstick clean, then screw dipstick into filler neck (B).
7. Tighten with wrench to compress washer. If spark plug is new, use 1/2 turn to compress washer appropriate amount. If reusing old spark plug, use 1/8 to 1/4 turn for proper washer compression. NOTE: An improperly tightened spark plug will become very hot and could damage the engine. 8. Reinstall the spark plug cap (B). B A Battery Replacement WARNING Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly corrosive and poisonous.
Cleaning the Spark Arrestor 1. Allow the engine to cool completely before servicing the spark arrestor. 2. Loosen the screw (A) to be able to remove clamp (B) and spark arrestor (C). 3. Carefully remove the carbon deposits from the spark arrestor screen with a wire brush. 4. Replace the spark arrestor if it is damaged. 5. Position the spark arrestor on the muffler and attach with the screws removed in step 2.
6 - Pull starter recoil several times to distribute oil in cylinder. 7 - Install spark plug. 8 - Pull recoil slowly until resistance is felt. This close valves so moisture cannot enter engine cylinder. Gently release recoil. 9 - Clean the generator and store in a cool, dry and well ventilated area out of direct sunlight. DRAINING THE FLOAT BOWL 1. Turn the fuel tank valve to the OFF position. 2. Locate the drain screw on the bottom of the carburetor float bowl. 3.
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine is running, but no AC output is available. 1. AC Circuit breaker is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 5. GFCI outlet is open (if equipped) 1. Check AC load and reset circuit breaker. 2. Contact customer service or authorized service center. 3. Check and repair. 4. Connect another device that is in good condition. 5. Correct ground fault and press reset button on GFCI outlet.
89 Page 33 24 7 8 1 10 11 12 13 5 9 10-1 6 18 21 25 84 19 23 22 85 20 88 3 87 10-3 10-4 2 86 4 1 82 81 28 15 56 10-2 80 79 28 75 74 28 73 28 26 28 34 17 58 28 14 27 52 72 53 71 55 62 63 64 65 68 67 66 69 70 56 54 56 41 44 35 83 76 58 35 83 77 42 43 56 61 78 32 83 36 55 35 53 52 54 16 24 24 38 37 35 83 36 30 30 30 31 29 29 29 28 40 39 16 57 30 29 46 50 51 49 16 33 59 48 47 45 78 60 PARTS DIAGRAM AND PARTS LIS
Parts List NO. Part Number Description Qty. NO. Part Number Description Qty. 1 30101-00326-00 Hex flange bolt M5*12 2 35 30125-00023-00 Hex flange nut M8 4 2 33082-00230-01 Motor tail cover 1 36 34030-00034-00 Vibration damping support 2 3 20044-00104-00 Voltage regulator 1 37 20090-02174-00 Frame assy.
Parts List NO. Part Number Description Qty. 73 31026-00338-00 Switch handle 1 74 33014-01737-00 Side baffle 1 75 70002-02338-00 Dust cap 1 76 34030-00044-00 Vibration damping support B 1 77 34030-00039-00 Vibration damping support A 1 78 34024-00003-00 Clamp 3 79 30112-00032-00 Self-tapping screws 2 80 20115-00163-00 CO alarm 1 81 20249-00144-00 Support parts 1 82 30101-00041-00 Hex flange nut M6 2 83 30125-00026-00 Hex flange nut M10 4 84 30101-00361-00 Hex flange bolt M8*1.
Field coil Sub coil Page 36 DC coil Main coil fuel cut solenoid O stepping motor ALTERNATOR O Y R B RO YP L B W V. Hz. H.
WARRANTY LIMITED WARRANTY KEEP YOUR RECEIPT. Proof of purchase will be required to substantiate any warranty claim. WHAT IS COVERED: A-iPower Corp.
other force majeure events beyond the control of the manufacturer. Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied. This warranty gives you specific legal rights which vary from state to state.
Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.
A-iPOWER WARRANTY REGISTRATION FORM Register your product by emailing this form to support@a-ipower.com or register on-line at: www.a-ipower.com. Registering your product is important , it provides the following protections: 1. You have record of product purchased 2. Customer Service can Better serve you for Warranty related issues 3.
Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com www.a-ipower.