Product specifications
AD-4329A Weighing Indicator Page 29
f-13
EXT4
The same as f-10
f-14
EXT5
The same as f-10
f-15
EXT6
The same as f-10
f-16
EXT7
The same as f-10
d: division (weighing interval) of first range.
*: factory settings (Initial settings).
s: second.
Comparator
Item
Parameter
Description
* 0 Not used
1
Upper/lower limit comparison. Set f-21, too.
f-20
Comparator function
2
Setpoint comparison
* 0 All data, always
1
Stable data
2
Data exceeding +5d
3
Stable data exceeding +5d
4
Data exceeding -5d to +5d
f-21
Comparator mode.
Condition to compare
data.
5
Stable data exceeding -5d to +5d
When f-20 is 1,
f-21 is effective.
Standard Serial Output
Item
Parameter
Description
* 0 Displayed data
1
Gross data
2
Net data
3
Tare value
f-30
Output Data
4
Gross data / Net data / Tare value
* 0 Stream mode
1
Auto print mode
f-31
Output mode
2
Manual print mode
* 0 Positive data only
f-32
Auto-print condition
1
Positive and negative data
* 0 Not used
f-33
Delay for continual data
1
Approximately 2 seconds
In case of f-31 0, the
f-33 is ineffective.
0
600 bps
1
1200 bps
f-34
Baud rate
* 2 2400 bps
bps: bit per second.
d: division (weighing interval) of first range.
*: factory settings (Initial settings).
6. Functions