Product specifications
Page 28 AD-4329A Weighing Indicator
Display
Item
Parameter
Description
* 0 10 times/s
f-03
Display update rate
1
5 times/s
The selection in the unstable
condition.
* 0
Manual + only
1 Manual + / -
2 Automatic + only
f-04
Accumulation Mode
3 Automatic + / -
The selection for the way of
adding data and kind of data.
0
Add data anytime
* 1 Above 5 d
2
Above 10 d
3
Above
20 d
f-05
Inhibit region for
accumulation
4
Above 50 d
The selection of the inhibit
region for accumulation
2 0
f-06
Disabling keys
A key is selected by the left
parameter
A key condition is selected by
the right parameter:
When specifying 1 at the right
parameter, this key does not
work.
Use the function to avoid
mis-operation of 8 keys on the
front panel without CAL key.
External Input
Item
Parameter
Description
* 0 Not used (No function)
1
Zero key
2
Tare key
3
Print key, key
4
Operate/Standby key
5
M+ key
6
Net/Gross key
7
Mode key
8
Gross display when shorting terminal.
9
Accumulation data display when shorting terminal.
10
Over signal. Gross over and display data are output.
f-10
EXT1
Function selection of
external input
11
All keys are enable when shorting terminal.
f-11
EXT2
The same as f-10
f-12
EXT3
The same as f-10
6. Functions
* 0
enable
1
disable
key
1
ON/OFF key
2
Preset tare key
3
M+ key
4
Mode key
5
Net/Gross key
6
Zero key
7
Tare key
8
Print key
key